EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of hip flexion angle on the elasticity and activity of the adductor longus and adductor magnus during isometric hip adduction

Keita Sekiguchi, Gakuto Nakao, Ginji Nara, Risa Adachi, Koki Ishiyama, Kazuyoshi Kozawa, Kotoka Kida, Shota Hirayama, Junpei Sawano, Keigo Taniguchi

Journal of Biomechanics Open · 2026-12 · 1 (3) · 100031

DOI: 10.1016/j.jbmo.2026.100031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanics Open, 2026-12. Verfasst von Keita Sekiguchi und 9 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We examined the effects of hip flexion angle on the shear modulus (an indicator of muscle elasticity measured via shear wave elastography) and the activity of the adductor longus and adductor magnus during isometric hip adduction.

Methods

Fifteen healthy young men performed isometric hip adduction at four intensities (0%, 25%, 50%, and 75% of maximal voluntary isometric contraction) and three hip flexion angles (0°, 45°, and 90°). The normalized root mean square (RMS) activity and shear modulus of the right adductor longus and adductor magnus were measured during each condition. A linear mixed-effects model assessed the effects of hip flexion angle and contraction intensity.

Results

The active shear modulus of the adductor magnus was significantly affected by hip flexion angle ( P < 0.001), with higher values at 0° (228.62 ± 103.26 kPa) and 45° (261.69 ± 158.02 kPa) than at 90° (172.35 ± 126.46 kPa). The RMS activity of the adductor longus was significantly affected by hip flexion angle ( P < 0.001), with greater values at 45° (0.556 ± 0.393) and 90° (0.597 ± 0.466) than at 0° (0.437 ± 0.298).

Conclusion

The activity of the adductor longus and the shear modulus of the adductor magnus depend on hip flexion angle. These findings highlight that electromyography activity and shear modulus may reflect different aspects of muscle properties of the adductor magnus and adductor longus in response to changes in hip flexion angle.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Sekiguchi, K., Nakao, G., Nara, G., Adachi, R., Ishiyama, K., Kozawa, K., Kida, K., Hirayama, S., Sawano, J., & Taniguchi, K. (2026). Effects of hip flexion angle on the elasticity and activity of the adductor longus and adductor magnus during isometric hip adduction. Journal of Biomechanics Open, 1(3), 100031. https://doi.org/10.1016/j.jbmo.2026.100031

Vancouver

Sekiguchi K, Nakao G, Nara G, Adachi R, Ishiyama K, Kozawa K, et al. Effects of hip flexion angle on the elasticity and activity of the adductor longus and adductor magnus during isometric hip adduction. Journal of Biomechanics Open. 2026;1(3):100031. doi:10.1016/j.jbmo.2026.100031

BibTeX
@article{Sekiguchi2026,
  author = {Sekiguchi, Keita and Nakao, Gakuto and Nara, Ginji and Adachi, Risa and Ishiyama, Koki and Kozawa, Kazuyoshi and Kida, Kotoka and Hirayama, Shota and Sawano, Junpei and Taniguchi, Keigo},
  title = {Effects of hip flexion angle on the elasticity and activity of the adductor longus and adductor magnus during isometric hip adduction},
  journal = {Journal of Biomechanics Open},
  year = {2026},
  volume = {1},
  number = {3},
  pages = {100031},
  doi = {10.1016/j.jbmo.2026.100031}
}
Kostenlos starten →