EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

High-throughput flow cytometry-based titration of a live attenuated rotavirus vaccine

Mafalda M Dias, Sofia B Carvalho, Jean-Philippe Matheise, Guillaume Van Beersel, Isabelle Knott, Patrícia Gomes-Alves, Paula M Alves

Journal of Biotechnology · 2025

DOI: 10.1016/j.jbiotec.2025.07.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biotechnology, 2025. Verfasst von Mafalda M Dias und 6 weiteren Autor:innen. Beteiligte Einrichtung: iBET, Instituto de Biologia Experimental e Tecnológica, Apartado 12, Oeiras 2781-901, Portugal; Instituto de Tecnologia Química e Biológica António X…. Hauptthemen laut MEDLINE: Rotavirus Vaccines, Flow Cytometry, High-Throughput Screening Assays, Rotavirus. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: GlaxoSmithKline Biologicals, Foundation for Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vaccine potency is a critical quality attribute to ensure vaccine's safety and efficacy. The standard potency assay for vaccines is the traditional cell culture infectious dose 50 % (CCID50). However, this method often yields highly variable results, presenting low sensitivity and requiring a lengthy analysis. Here, we report a flow cytometry-based method for potency assessment of the Rotarix rotavirus vaccine. This method quantifies infected cells by detecting VP7 viral protein in MA104 cells, integrating fluorescence-automated cell counting with a high-throughput system. Determination of adequate cell seeding timepoint, target cell concentration and endpoint after infection are key parameters for the precision, robustness, and accuracy of titer determination. We established optimized assay conditions for lyophilized and final vaccine formulations. Data from both workflows are in line with the CCID50 range of concentrations. The coefficient of variation for inter- and intra-assay for both formulations is ≈ 2 %. Moreover, the flow cytometry method reduced the hands-on and analysis time by at least 4 days, offering a rapid high-throughput alternative tool to streamline the challenges associated with potency testing for viral-based vaccines, impacting therapeutics time to market.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rotavirus VaccinesFlow CytometryHigh-Throughput Screening AssaysRotavirusVaccines, AttenuatedAnimalsCell LineHumans

Stichwörter der Autor:innen

Batch releaseBioanalyticsFlow cytometryHigh-throughput analysisPotencyRotavirus vaccine

Substanzen

Rotavirus VaccinesVaccines, AttenuatedRIX4414 vaccine

Autor:innen und Institutionen

  • iBET, Instituto de Biologia Experimental e Tecnológica, Apartado 12, Oeiras 2781-901, Portugal; Instituto de Tecnologia Química e Biológica António Xavier, Universidade Nova de Lisboa, Av. da República, Oeiras 2780-157,…
  • GSK, Avenue Fleming 20, Wavre 1300, Belgium.
  • GSK, Rue de l'Institut 89, Rixensart 1330, Belgium.

Förderung

  • GlaxoSmithKline Biologicals
  • Foundation for Science and Technology

Zitieren

APA

Dias, M. M., Carvalho, S. B., Matheise, J. P., Van Beersel, G., Knott, I., Gomes-Alves, P., & Alves, P. M. (2025). High-throughput flow cytometry-based titration of a live attenuated rotavirus vaccine. Journal of Biotechnology. https://doi.org/10.1016/j.jbiotec.2025.07.004

Vancouver

Dias MM, Carvalho SB, Matheise JP, Van Beersel G, Knott I, Gomes-Alves P, et al. High-throughput flow cytometry-based titration of a live attenuated rotavirus vaccine. Journal of Biotechnology. 2025. doi:10.1016/j.jbiotec.2025.07.004

BibTeX
@article{Dias2025,
  author = {Dias, Mafalda M and Carvalho, Sofia B and Matheise, Jean-Philippe and Van Beersel, Guillaume and Knott, Isabelle and Gomes-Alves, Patrícia and Alves, Paula M},
  title = {High-throughput flow cytometry-based titration of a live attenuated rotavirus vaccine},
  journal = {Journal of Biotechnology},
  year = {2025},
  doi = {10.1016/j.jbiotec.2025.07.004}
}
Kostenlos starten →