EUVIMEDEUVIMED entdecken
Crossref

Accuracy and efficacy of Ion robotic-assisted bronchoscopic fine needle aspiration of lung lesions

Bernadette M Boac, Manita Kanathanavanich, Xiaomo Li, Taryne Imai, Xuemo Fan, Ann E Walts, Alberto M Marchevsky, Shikha Bose

Journal of the American Society of Cytopathology · 2024-11 · 13 (6) · 420-430

DOI: 10.1016/j.jasc.2024.08.129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society of Cytopathology, 2024-11. Verfasst von Bernadette M Boac und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Cedars Sinai Medical Center, Los Angeles, California. Hauptthemen laut MEDLINE: Lung Neoplasms, Bronchoscopy, Robotic Surgical Procedures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The Ion Endoluminal Platform (ION) (IEPI Intuitive, Sunnyvale, CA), a minimally invasive robotic-assisted bronchoscopy platform, was recently US Food and Drug Administration approved for the performance of fine needle aspirations (FNAs) and biopsies of peripheral lung lesions. Rapid on-site intraoperative diagnosis (IOD) of FNAs and/or frozen section of biopsies help surgeons confirm adequate sampling of the targeted lesion and allow definitive treatment in selected cases. MATERIALS AND METHODS: We retrospectively reviewed our experience with all FNAs of lung lesions sampled by interventional pulmonologists and thoracic surgeons using Ion from September 2020 to December 2022. IOD rendered during adequacy assessment were compared with final cytology diagnoses (Cyto-FD) and the ultimate final diagnoses (U-FD). The U-FD was based on the sum of all clinical, imaging, cytologic, and histologic diagnoses of the lung lesion which the clinical team used to treat the patient. RESULTS: The IOD and Cyto-FD were concordant in 62% of the 423 lesions that underwent intraoperative evaluation, yielding a sensitivity of 67% and a specificity of 99% for malignancy. The Cyto-FD and U-FD were concordant in 51% of the lesions with a sensitivity and specificity for malignancy of 66% and 100%, respectively. CONCLUSIONS: IODs rendered during Ion were highly accurate but only moderately sensitive for a diagnosis of malignancy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsBronchoscopyRobotic Surgical ProceduresHumansRetrospective StudiesMaleFemaleMiddle AgedAgedBiopsy, Fine-NeedleLungAdultAged, 80 and overSensitivity and Specificity

Stichwörter der Autor:innen

Fine needle aspiration cytologyIntraoperative evaluationIon endoluminal platformPulmonary cytopathologyRapid on-site evaluation (ROSE)Robotic assisted bronchoscopyShape sensing technology

Autor:innen und Institutionen

  • Department of Pathology, Cedars Sinai Medical Center, Los Angeles, California.
  • Department of Thoracic Surgery, Cedars Sinai Medical Center, Los Angeles, California.
  • Department of Pathology, Cedars Sinai Medical Center, Los Angeles, California. Electronic address: shikha.bose@cshs.org.

Zitieren

APA

Boac, B. M., Kanathanavanich, M., Li, X., Imai, T., Fan, X., Walts, A. E., Marchevsky, A. M., & Bose, S. (2024). Accuracy and efficacy of Ion robotic-assisted bronchoscopic fine needle aspiration of lung lesions. Journal of the American Society of Cytopathology, 13(6), 420-430. https://doi.org/10.1016/j.jasc.2024.08.129

Vancouver

Boac BM, Kanathanavanich M, Li X, Imai T, Fan X, Walts AE, et al. Accuracy and efficacy of Ion robotic-assisted bronchoscopic fine needle aspiration of lung lesions. Journal of the American Society of Cytopathology. 2024;13(6):420-430. doi:10.1016/j.jasc.2024.08.129

BibTeX
@article{Boac2024,
  author = {Boac, Bernadette M and Kanathanavanich, Manita and Li, Xiaomo and Imai, Taryne and Fan, Xuemo and Walts, Ann E and Marchevsky, Alberto M and Bose, Shikha},
  title = {Accuracy and efficacy of Ion robotic-assisted bronchoscopic fine needle aspiration of lung lesions},
  journal = {Journal of the American Society of Cytopathology},
  year = {2024},
  volume = {13},
  number = {6},
  pages = {420--430},
  doi = {10.1016/j.jasc.2024.08.129}
}
Kostenlos starten →