EUVIMEDEUVIMED entdecken
Multizentrische StudiePragmatische StudieRandomisierte kontrollierte StudieVergleichsstudie

Radiation Dose Associated With CT in the Watch the Spot Trial: A Pragmatic Trial of Less Versus More Intensive Strategies for Active Follow-Up of Patients With Small Pulmonary Nodules

Rebecca Smith-Bindman, Diana L Miglioretti, Yueju Li, Lihong Qi, Evan de Bie, Beth Creekmur, Debra P Ritzwoller, Kim L Sandler, Debra S Dyer, Karen Kelly, Michael K Gould

Journal of the American College of Radiology · 2025-12 · 22 (12) · 1578-1588

DOI: 10.1016/j.jacr.2025.10.010 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of the American College of Radiology, 2025-12. Verfasst von Rebecca Smith-Bindman und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology and Biostatistics, Department of Obstetrics, Gynecology and Reproductive Sciences, and the Philip R. Lee Institute for Hea…. Hauptthemen laut MEDLINE: Radiation Dosage, Tomography, X-Ray Computed, Lung Neoplasms, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Patient-Centered Outcomes Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Watch the Spot is a cluster-randomized pragmatic clinical trial comparing less versus more intensive surveillance strategies for small pulmonary nodules. This article describes radiation doses from screening and follow-up imaging. METHODS: In all, 34,686 patients with small nodules were enrolled across 24 US sites (March 2017 to July 2019). Dose estimates were available from 21 sites and reported as size-adjusted CT dose index-volume (CTDIvol), dose-length product (DLP), and effective dose standardized to an 80-kg patient. Mean (SD) doses for screening and follow-up CTs and the proportion exceeding ACR/AAPM dose thresholds were calculated. Two-year cumulative follow-up imaging doses (excluding baseline scans) were estimated from 22 sites and compared between study arms. RESULTS: Radiation doses varied substantially across sites. For screening, mean size-adjusted CTDIvol ranged from 1.6 mGy (SD = 0.43) to 8.0 mGy (SD = 2.5), DLP from 62 mGy-cm (SD = 16) to 301 mGy-cm (SD = 102), and effective dose from 1.7 mSv (SD = 0.46) to 11 mSv (SD = 3.7). Follow-up scans had higher mean doses and wider variation: CTDIvol ranged from 4.0 mGy (SD = 3.5) to 14 mGy (SD = 9.8), DLP from 157 mGy-cm (SD = 143) to 443 mGy-cm (SD = 395), and effective dose from 5.1 mSv (SD = 5.4) to 16 mSv (SD = 14). Overall, 44% of screening and 61% of follow-up scans exceeded ACR/AAPM CTDIvol thresholds, and 81% and 88% exceeded DLP thresholds. Cumulative follow-up doses were similar between study arms (18.6 versus 19.0 mSv, P = .90). CONCLUSION: Two-year cumulative radiation dose was similar for patients in the less and more intensive surveillance arms; however, patient size-adjusted doses both for screening and follow-up CTs varied widely within and across sites and frequently exceeded recommended thresholds.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageTomography, X-Ray ComputedLung NeoplasmsMultiple Pulmonary NodulesSolitary Pulmonary NoduleHumansMaleFemaleMiddle AgedAgedFollow-Up StudiesUnited States

Stichwörter der Autor:innen

CT radiation doselung cancer screeninglung nodule surveillancepulmonary nodulerandomized trial

Autor:innen und Institutionen

  • Department of Epidemiology and Biostatistics, Department of Obstetrics, Gynecology and Reproductive Sciences, and the Philip R. Lee Institute for Health Policy Studies, University of California, San Francisco, San Franc…
  • Division Chief of Biostatistics, Department of Public Health Sciences, University of California, Davis, Davis, California.
  • Department of Public Health Sciences, University of California, Davis, Davis, California.
  • Department of Research & Evaluation, Kaiser Permanente Southern California, Pasadena, California.
  • Institute of Health Research, Kaiser Permanente Colorado, Aurora, Colorado.
  • Department of Radiology, Vanderbilt University, Nashville, Tennessee.

Förderung

  • Patient-Centered Outcomes Research Institute

Zitieren

APA

Smith-Bindman, R., Miglioretti, D. L., Li, Y., Qi, L., de Bie, E., Creekmur, B., Ritzwoller, D. P., Sandler, K. L., Dyer, D. S., Kelly, K., & Gould, M. K. (2025). Radiation Dose Associated With CT in the Watch the Spot Trial: A Pragmatic Trial of Less Versus More Intensive Strategies for Active Follow-Up of Patients With Small Pulmonary Nodules. Journal of the American College of Radiology, 22(12), 1578-1588. https://doi.org/10.1016/j.jacr.2025.10.010

Vancouver

Smith-Bindman R, Miglioretti DL, Li Y, Qi L, de Bie E, Creekmur B, et al. Radiation Dose Associated With CT in the Watch the Spot Trial: A Pragmatic Trial of Less Versus More Intensive Strategies for Active Follow-Up of Patients With Small Pulmonary Nodules. Journal of the American College of Radiology. 2025;22(12):1578-1588. doi:10.1016/j.jacr.2025.10.010

BibTeX
@article{SmithBindman2025,
  author = {Smith-Bindman, Rebecca and Miglioretti, Diana L and Li, Yueju and Qi, Lihong and de Bie, Evan and Creekmur, Beth and Ritzwoller, Debra P and Sandler, Kim L and Dyer, Debra S and Kelly, Karen and Gould, Michael K},
  title = {Radiation Dose Associated With CT in the Watch the Spot Trial: A Pragmatic Trial of Less Versus More Intensive Strategies for Active Follow-Up of Patients With Small Pulmonary Nodules},
  journal = {Journal of the American College of Radiology},
  year = {2025},
  volume = {22},
  number = {12},
  pages = {1578--1588},
  doi = {10.1016/j.jacr.2025.10.010}
}
Kostenlos starten →