Radiologist Interaction with Artificial Intelligence-Generated Preliminary Reports: A Longitudinal Multireader Study
Journal of the American College of Radiology · 2026-02 · 23 (2) · 292-298
DOI: 10.1016/j.jacr.2025.09.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American College of Radiology, 2026-02. Verfasst von Eun Kyoung Hong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mass General Brigham, Boston, Massachusetts. Electronic address: amyh0803@gmail.com. Hauptthemen laut MEDLINE: Radiography, Thoracic, Artificial Intelligence, Radiologists, Radiology Information Systems. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To investigate the integration of multimodal AI-generated reports into radiology workflow over time, focusing on their impact on efficiency, acceptability, and report quality. METHODS: A multicase, multireader study involved 756 publicly available chest radiographs interpreted by five radiologists using preliminary reports generated by a radiology-specific multimodal AI model, divided into 7 sequential batches of 108 radiographs each. Two thoracic radiologists assessed the final reports using RADPEER criteria for agreement and 5-point Likert scale for quality. Reading times, rate of acceptance without modification, agreement, and quality scores were measured, with statistical analyses evaluating trends across seven sequential batches. RESULTS: Radiologists' reading times for chest radiographs decreased from 25.8 seconds in batch 1 to 19.3 seconds in batch 7 (P < .001). Acceptability increased from 54.6% to 60.2% (P < .001), with normal chest radiographs demonstrating high rates (68.9%) compared with abnormal chest radiographs (52.6%; P < .001). Median agreement and quality scores remained stable for normal chest radiographs but varied significantly for abnormal chest radiographs (all P < .05). DISCUSSION: The introduction of AI-generated reports improved efficiency of chest radiograph interpretation, and acceptability increased over time. However, agreement and quality scores showed variability, particularly in abnormal cases, emphasizing the need for oversight in the interpretation of complex chest radiographs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Mass General Brigham, Boston, Massachusetts. Electronic address: amyh0803@gmail.com.
- Department of Radiology, Asan Medical Center, Seoul, South Korea.
- Department of Radiology, Mass General Brigham, Boston, Massachusetts.
- Department of Radiology, Mass General Brigham, Boston, Massachusetts; Medical Director of Thoracic Imaging.
Zitieren
APA
Hong, E. K., Suh, C. H., Nukala, M., Esfahani, A., Licaros, A., Madan, R., Hunsaker, A., & Hammer, M. (2026). Radiologist Interaction with Artificial Intelligence-Generated Preliminary Reports: A Longitudinal Multireader Study. Journal of the American College of Radiology, 23(2), 292-298. https://doi.org/10.1016/j.jacr.2025.09.015
Vancouver
Hong EK, Suh CH, Nukala M, Esfahani A, Licaros A, Madan R, et al. Radiologist Interaction with Artificial Intelligence-Generated Preliminary Reports: A Longitudinal Multireader Study. Journal of the American College of Radiology. 2026;23(2):292-298. doi:10.1016/j.jacr.2025.09.015
BibTeX
@article{Hong2026,
author = {Hong, Eun Kyoung and Suh, Chong Hyun and Nukala, Monika and Esfahani, Azadehsadat and Licaros, Andro and Madan, Rachna and Hunsaker, Andetta and Hammer, Mark},
title = {Radiologist Interaction with Artificial Intelligence-Generated Preliminary Reports: A Longitudinal Multireader Study},
journal = {Journal of the American College of Radiology},
year = {2026},
volume = {23},
number = {2},
pages = {292--298},
doi = {10.1016/j.jacr.2025.09.015}
}
EUVIMED