EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Concordance between LDL-C estimated by various formulas and directly measured LDL-C

David Gabriel David-Pardo, Álvaro J Ruiz, Óscar Mauricio Muñoz Velandia, Ángel Alberto García Peña, Diana Ximena Salgado García, Julieth Andrea Arcila Matiz

Journal of Clinical Lipidology · 2024

DOI: 10.1016/j.jacl.2024.08.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Lipidology, 2024. Verfasst von David Gabriel David-Pardo und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Pontificia Universidad Javeriana, Bogotá, Colombia (Drs David-Pardo, Ruiz, Muñoz Velandia, García Peña); Department of Internal M…. Hauptthemen laut MEDLINE: Cholesterol, LDL. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although direct measurement of low-density lipoprotein cholesterol (LDL-C) in blood is possible, there are several formulas for its estimation. The performance and concordance of these formulas have not been evaluated in Colombia. OBJECTIVE: To determine the concordance between LDL-C directly measured using the enzymatic technique and existing methods to calculate it. METHODS: Study of diagnostic tests, and concordance. We analyzed complete lipid profile samples, which included direct measurement of LDL-C, from 2014 to 2022 at Hospital Universitario San Ignacio (Bogotá, Colombia). The direct LDL-C measurements were compared with estimations using the DeLong, Sampson, Friedewald, extended Martin/Hopkins, Anandaraja, and Cordova methods. Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were employed, conducting subgroup analyses based on triglycerides (TG), and LDL-C levels. Kappa coefficients assessed agreement in LDL-C risk categories according to dyslipidemia guidelines. RESULTS: A total of 2144 samples were evaluated. The formulas with the best CCC were DeLong (0.971) and Sampson (0.969), with no relevant differences. The extended Martin/Hopkins formula (0.964) and the Friedewald formula (0.964) also performed well. The Anandaraja (0.921) and Cordova (0.881) equations exhibited inferior performance. For all formulas, a decrease in concordance was observed when TG were ≥ 400 mg/dL or when LDL-C was

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cholesterol, LDLHumansFemaleMaleMiddle AgedDyslipidemiasTriglyceridesColombiaAdultAged

Stichwörter der Autor:innen

Diagnostic testsFriedewaldLDL-CLin's concordance correlation coefficientdyslipidemia

Substanzen

Cholesterol, LDLTriglycerides

Autor:innen und Institutionen

  • School of Medicine, Pontificia Universidad Javeriana, Bogotá, Colombia (Drs David-Pardo, Ruiz, Muñoz Velandia, García Peña); Department of Internal Medicine, Hospital Universitario San Ignacio, Bogotá, Colombia (Drs Dav…
  • Ciencias de laboratorio clínico, Hospital Universitario San Ignacio, Bogotá, Colombia (Drs García and Matiz).

Zitieren

APA

David-Pardo, D. G., Ruiz, Á. J., Muñoz Velandia, Ó. M., García Peña, Á. A., Salgado García, D. X., & Arcila Matiz, J. A. (2024). Concordance between LDL-C estimated by various formulas and directly measured LDL-C. Journal of Clinical Lipidology. https://doi.org/10.1016/j.jacl.2024.08.009

Vancouver

David-Pardo DG, Ruiz ÁJ, Muñoz Velandia ÓM, García Peña ÁA, Salgado García DX, Arcila Matiz JA. Concordance between LDL-C estimated by various formulas and directly measured LDL-C. Journal of Clinical Lipidology. 2024. doi:10.1016/j.jacl.2024.08.009

BibTeX
@article{DavidPardo2024,
  author = {David-Pardo, David Gabriel and Ruiz, Álvaro J and Muñoz Velandia, Óscar Mauricio and García Peña, Ángel Alberto and Salgado García, Diana Ximena and Arcila Matiz, Julieth Andrea},
  title = {Concordance between LDL-C estimated by various formulas and directly measured LDL-C},
  journal = {Journal of Clinical Lipidology},
  year = {2024},
  doi = {10.1016/j.jacl.2024.08.009}
}
Kostenlos starten →