Effects of Dual-Energy Lattice-Tip Catheter Ablation of Ventricular Arrhythmias on Cardiac Implantable Electronic Device Performance
JACC: Clinical Electrophysiology · 2026-10
DOI: 10.1016/j.jacep.2026.08.028 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2026-10. Verfasst von Ehsan Mahmoodi und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The Sphere-9 lattice-tip catheter (Affera, Medtronic) enables delivery of both radiofrequency ablation (RFA) and pulsed field ablation (PFA) for ventricular arrhythmia (VA) ablation. Data on its impact on cardiac implantable electronic devices (CIEDs) are limited. OBJECTIVES: This study sought to evaluate changes in CIED function following VA ablation using the Sphere-9 catheter. METHODS: We reviewed 65 consecutive patients (median age 71 years, 94% male, 63% ischemic cardiomyopathy, median left ventricular ejection fraction 31%) with pre-existing CIEDs who underwent VA ablation (62 ventricular tachycardia [95%], 3 premature ventricular contraction [5%]) using the Sphere-9 catheter (combined RFA/PFA (53 [82%]), RFA alone (6 [9%]), PFA alone (6 [9%])). Device interrogation was performed within 30 days preprocedure, within 7 days postprocedure, and at 3-month (+/- 30 days) follow-up. RESULTS: At 3-months, right ventricular leads demonstrated reduced sensing amplitude (11.7-10.0 mV, P = 0.04), pacing impedance (441-422 Ω, P < 0.001), shock impedance (64-59 Ω, P = 0.01), and increased capture threshold (0.9-1.0 V at 0.4-0.5 milliseconds, P = 0.03). Left ventricular (LV) leads demonstrated reduced pacing impedance (544-475 Ω, P = 0.04), whereas LV capture threshold remained elevated (1.0-1.4 V, P = 0.08). Right atrial lead parameters remained stable. No patient required CIED revision. One patient experienced cardiac resynchronization therapy-D pulse generator failure during PFA delivery 7.5 mm from an LV lead tip electrode, requiring generator replacement. CONCLUSIONS: Ventricular arrhythmia ablation using the Sphere-9 dual-energy lattice-tip catheter was associated with small but persistent changes in right and left ventricular lead parameters. Serious CIED interactions were uncommon, and further studies are needed to better understand the underlying mechanisms.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address: santanp3@ccf.org.
Zitieren
APA
Mahmoodi, E., Younis, A., Higuchi, K., Sroubek, J., Lee, J. Z., Chung, R., Dasa, O., Nakhla, S., Paulin-Mosho, B., Hight, N., Varma, N., Hussein, A. A., Taigen, T., Kanj, M., Bhargava, M., Saliba, W. I., Wazni, O. M., & Santangeli, P. (2026). Effects of Dual-Energy Lattice-Tip Catheter Ablation of Ventricular Arrhythmias on Cardiac Implantable Electronic Device Performance. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.08.028
Vancouver
Mahmoodi E, Younis A, Higuchi K, Sroubek J, Lee JZ, Chung R, et al. Effects of Dual-Energy Lattice-Tip Catheter Ablation of Ventricular Arrhythmias on Cardiac Implantable Electronic Device Performance. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.08.028
BibTeX
@article{Mahmoodi2026,
author = {Mahmoodi, Ehsan and Younis, Arwa and Higuchi, Koji and Sroubek, Jakub and Lee, Justin Z and Chung, Roy and Dasa, Osama and Nakhla, Shady and Paulin-Mosho, Brittany and Hight, Nolan and Varma, Niraj and Hussein, Ayman A and Taigen, Tyler and Kanj, Mohamed and Bhargava, Mandeep and Saliba, Walid I and Wazni, Oussama M and Santangeli, Pasquale},
title = {Effects of Dual-Energy Lattice-Tip Catheter Ablation of Ventricular Arrhythmias on Cardiac Implantable Electronic Device Performance},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
doi = {10.1016/j.jacep.2026.08.028}
}
EUVIMED