Comparing High-Density Electroanatomic Mapping and MRI
JACC: Clinical Electrophysiology · 2026
DOI: 10.1016/j.jacep.2026.01.054 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift JACC: Clinical Electrophysiology, 2026. Verfasst von Michela Casella und 18 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Clinical Specialistic and Odontostomatologic Sciences, …. Hauptthemen laut MEDLINE: Cardiomyopathies, Magnetic Resonance Imaging, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Risk stratification for sudden cardiac death (SCD) in nonischemic cardiomyopathy (NICM) relies on identification of myocardial scars, the substrate for ventricular arrhythmias. Scar assessment is typically performed with late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). LGE-CMR images can be postprocessed by dedicated software to generate 3D scar maps that can be integrated with electroanatomic voltage mapping (EVM). OBJECTIVES: This study sought to assess the concordance and reliability between LGE-CMR-derived scar maps and EVM performed with a high-density catheter in myocardial tissue characterization. METHODS: In this multicenter, observational, cross-sectional study, we included 36 NICM patients who underwent left ventricular EVM for arrhythmic and SCD risk stratification. Each patient underwent LGE-CMR, processed with the use of dedicated software to delineate scar core and border zones. EVM depicted scar regions with the use of omnipolar technology (OT), bipolar (BIP), and unipolar (UNI) acquisition modes. Cohen's kappa coefficient and Bland-Altman methods were used to assess agreement and reliability, respectively. RESULTS: The UNI configuration showed the best agreement with subepicardial LGE-CMR maps (κ: 0.93; positive predictive value [PPV]: 97.2%; negative predictive value [NPV]: 86.5%), and OT outperformed BIP for subendocardial layers (κ: 0.97 vs 0.74; PPV: 96% vs 76%; NPV: 100% vs 96%). In reliability analysis, OT showed the least systematic bias and the narrowest limits of agreement with LGE-CMR-derived scar maps, and was associated with higher point density maps. Whereas BIP mapping had the best agreement with the 10%-20% myocardial layer, OT best aligned with the 20%-40% myocardial layer. CONCLUSIONS: EVM had high agreement with LGE-CMR images and accurately delineated endo-mid-myocardial substrates, supporting its potential role in substrate characterization for NICM patients unfit for LGE-CMR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Clinical Specialistic and Odontostomatologic Sciences, Marche Polytechnic University, Ancona, Italy; Maria Cecilia Hospital,…
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy. Electronic address: leonardodangelo00@gm…
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy.
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy.
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
Zitieren
APA
Casella, M., D'Angelo, L., Narducci, M. L., Compagnucci, P., Volpato, G., Valeri, Y., Campanelli, F., Finori, L., Cipolletta, L., Parisi, Q., Giordano, F., Stronati, G., Fogante, M., Schicchi, N., Ciliberti, G., Noventa, F., Guerra, F., Pelargonio, G., & Russo, A. D. (2026). Comparing High-Density Electroanatomic Mapping and MRI. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.01.054
Vancouver
Casella M, D'Angelo L, Narducci ML, Compagnucci P, Volpato G, Valeri Y, et al. Comparing High-Density Electroanatomic Mapping and MRI. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.01.054
BibTeX
@article{Casella2026,
author = {Casella, Michela and D'Angelo, Leonardo and Narducci, Maria L and Compagnucci, Paolo and Volpato, Giovanni and Valeri, Yari and Campanelli, Francesca and Finori, Luca and Cipolletta, Laura and Parisi, Quintino and Giordano, Federica and Stronati, Giulia and Fogante, Marco and Schicchi, Nicolò and Ciliberti, Giuseppe and Noventa, Franco and Guerra, Federico and Pelargonio, Gemma and Russo, Antonio Dello},
title = {Comparing High-Density Electroanatomic Mapping and MRI},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
doi = {10.1016/j.jacep.2026.01.054}
}
EUVIMED