Figure-of-8 Suture With a 3-Way Tap Versus Manual Compression After Atrial Fibrillation Ablation
JACC: Clinical Electrophysiology · 2026
DOI: 10.1016/j.jacep.2026.01.014 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2026. Verfasst von Mark T Mills und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Liverpool Heart & Chest Hospital, Liverpool, United Kingdom; Liverpool Centre for Cardiovascular Science at University of L…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Suture Techniques, Sutures. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: ) offers a simple and low-cost alternative to manual compression (MC). OBJECTIVES: The HARNESS (Haemostasis After Venous Access in Atrial Fibrillation Catheter Ablation) randomized controlled trial evaluated the efficacy of Fo8TAP and its impact on post-procedural bed rest duration. METHODS: with 2-hour bed rest (TAP-2). The primary endpoint of any access site complication before hospital discharge was assessed for superiority (TAP-4 vs MC-4) and noninferiority (TAP-2 vs TAP-4). Bleeding was graded from 1 (minor) to 4 (life-threatening). Secondary endpoints included times to hemostasis, catheter laboratory exit, and mobilization. RESULTS: (MC-4: 16 min; TAP-4: 9 min; TAP-2: 8 min; P < 0.001). Median time to mobilization was shortest with TAP-2 (MC-4: 242 min; TAP-4: 241 min; TAP-2: 122 min; P < 0.001). CONCLUSIONS: was superior to MC in lowering the incidence of access site complications and was associated with health care efficiencies. However, a 2-hour bed rest strategy failed to meet noninferiority criteria versus 4 hours. (Haemostasis After Venous Access in Atrial Fibrillation Catheter Ablation [HARNESS]; NCT06470555).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Liverpool Heart & Chest Hospital, Liverpool, United Kingdom; Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest…
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom; Research Department, Liverpool Heart & Chest Hosp…
- Research Department, Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.
- Department of Cardiology, Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.
Zitieren
APA
Mills, M. T., Calvert, P., Tidbury, L., Wilson, K., Evans, T., de Francesco, L., Najm, A., Tripathi, R., Farinha, J. M., Xydis, P., Thu, K., Snowdon, R., Borbas, Z., Waktare, J., Mahida, S. N., Denham, N., Ashrafi, R., Todd, D., Modi, S., …, & Gupta, D. (2026). Figure-of-8 Suture With a 3-Way Tap Versus Manual Compression After Atrial Fibrillation Ablation. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.01.014
Vancouver
Mills MT, Calvert P, Tidbury L, Wilson K, Evans T, de Francesco L, et al. Figure-of-8 Suture With a 3-Way Tap Versus Manual Compression After Atrial Fibrillation Ablation. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.01.014
BibTeX
@article{Mills2026,
author = {Mills, Mark T and Calvert, Peter and Tidbury, Laurence and Wilson, Keith and Evans, Thomas and de Francesco, Luca and Najm, Ali and Tripathi, Rajiv and Farinha, Jose Maria and Xydis, Panagiotis and Thu, Kaung and Snowdon, Richard and Borbas, Zoltan and Waktare, Johan and Mahida, Saagar N and Denham, Nathan and Ashrafi, Reza and Todd, Derick and Modi, Simon and Luther, Vishal and Gupta, Dhiraj},
title = {Figure-of-8 Suture With a 3-Way Tap Versus Manual Compression After Atrial Fibrillation Ablation},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
doi = {10.1016/j.jacep.2026.01.014}
}
EUVIMED