Multiparametric Electrogram Feature Analysis for Ventricular Tachycardia Functional Extra-Stimulus Substrate Mapping
JACC: Clinical Electrophysiology · 2026-04 · 12 (4) · 702-715
DOI: 10.1016/j.jacep.2025.11.006 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2026-04. Verfasst von Joseph Mayer und 15 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Research Group, Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom; Institute for …. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Hospital Clínic de Barcelona.
Abstract (Originalsprache)
BACKGROUND: Functional extra-stimulus (ES) substrate mapping has been shown to reduce the recurrence of ventricular tachycardia (VT) compared with intrinsic rhythm mapping. However, there is no standardized approach to functional ES mapping. OBJECTIVES: This study investigated the accuracy of a range of functional ES mapping methods using S1 and S2 ES, evaluating multiple electrogram (EGM) components. METHODS: A multicenter, international VT ablation cohort was investigated. Offline annotation of stimulus artifact, first deflection, last deflection, and near-field (NF) EGM components enabled construction of 6 functional ES maps. Comprehensive accuracy testing was performed in identifying the critical arrhythmogenic substrate. RESULTS: Nineteen patients (mean age 61.1 ± 14.2 years; mean ejection fraction 31.7% ± 11.3%) were included. The EGM duration-based decremental evoked potential (DeEP) map had the highest area under the receiver-operating characteristic curve (0.804 ± 0.107; P < 0.001), with an optimal decrement threshold of 20 milliseconds (F1 score, P = 0.014) or 30 milliseconds (F1 score, P = 0.029). The inclusion of latency to EGM duration, assessed with a stimulus to the last deflection-based DeEP map, did not improve diagnostic performance (area under the receiver-operating characteristic curve 0.625 ± 0.173). Automated NF EGM annotation did not improve accuracy with or without the inclusion of latency. The EGM duration DeEP map exhibited superior accuracy across almost all left ventricular locations, providing higher precision in lateral/basal regions (Δ average precision, 0.24 ± 0.04; P < 0.001). CONCLUSIONS: Functional ES mapping using EGM duration prolongation DeEP maps yielded the highest accuracy in defining the arrhythmogenic substrate. The inclusion of latency or annotation of NF EGM components does not improve functional substrate mapping accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart Rhythm Research Group, Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom; Institute for Cardio-Metabolic Medicine, University Hospital Coventry and Warwickshi…
- Heart Rhythm Research Group, Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom; Institute of Cardiovascular Science, University College London, London, United Kingd…
- Electrophysiology Division, Abbott Laboratories, Solihull, United Kingdom.
- Hopital Henri Mondor Albert Chenevier, Inserm U955, Paris, France.
- Heart Rhythm Research Group, Division of Biomedical Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom; Sussex Cardiac Centre, Royal Sussex County Hospital, Brighton, United Kingdom.
- Department of Cardiology, Royal Stoke University Hospital, Stoke-on-Trent, United Kingdom.
Förderung
- Hospital Clínic de Barcelona
Zitieren
APA
Mayer, J., Al-Sheikhli, J., Wang, X., Siang, R., Patchett, I., Winter, J., Lellouche, N., Manoharan, K., Trung Phan, T., Calvo, J. J., Porta-Sánchez, A., Roca-Luque, I., Silberbauer, J., O'Shea, C., Minhas, F., & Dhanjal, T. (2026). Multiparametric Electrogram Feature Analysis for Ventricular Tachycardia Functional Extra-Stimulus Substrate Mapping. JACC: Clinical Electrophysiology, 12(4), 702-715. https://doi.org/10.1016/j.jacep.2025.11.006
Vancouver
Mayer J, Al-Sheikhli J, Wang X, Siang R, Patchett I, Winter J, et al. Multiparametric Electrogram Feature Analysis for Ventricular Tachycardia Functional Extra-Stimulus Substrate Mapping. JACC: Clinical Electrophysiology. 2026;12(4):702-715. doi:10.1016/j.jacep.2025.11.006
BibTeX
@article{Mayer2026,
author = {Mayer, Joseph and Al-Sheikhli, Jaffar and Wang, Xuezhe and Siang, Rafaella and Patchett, Ian and Winter, James and Lellouche, Nicolas and Manoharan, Karthick and Trung Phan, Thanh and Calvo, Justo Juliá and Porta-Sánchez, Andreu and Roca-Luque, Ivo and Silberbauer, John and O'Shea, Christopher and Minhas, Fayyaz and Dhanjal, Tarvinder},
title = {Multiparametric Electrogram Feature Analysis for Ventricular Tachycardia Functional Extra-Stimulus Substrate Mapping},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
volume = {12},
number = {4},
pages = {702--715},
doi = {10.1016/j.jacep.2025.11.006}
}
EUVIMED