Pulmonary Vein Isolation Only for Atrial Fibrillation With Heart Failure (POLAR-HF)
JACC: Clinical Electrophysiology · 2026
DOI: 10.1016/j.jacep.2025.09.041 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift JACC: Clinical Electrophysiology, 2026. Verfasst von Andreas A Boehmer und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St. Josefs-Hospital Wiesbaden, Wiesbaden Germany; Department of Medicine, Montreal Heart Institute, Université de Montréal,…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Heart Failure, Catheter Ablation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Herzinsuffizienz
Abstract (Originalsprache)
BACKGROUND: Atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF) are both associated with increased morbidity and mortality. Ablation-based rhythm control, particularly using radiofrequency ablation with disparate strategies, has demonstrated clinical benefit. However, prospective data evaluating a pulmonary vein isolation (PVI)-only strategy in HFrEF are lacking, and no studies have directly compared ablation efficacy between patients with and without HFrEF. OBJECTIVES: This study sought to assess whether a PVI-only approach using cryoballoon ablation in patients with HFrEF (LVEF ≤40%) is noninferior to PVI-only in patients without HFrEF regarding rhythm control efficacy, and to describe safety outcomes. METHODS: We conducted a prospective, investigator-initiated, single-center, noninferiority, observational study with propensity score matching. The primary efficacy endpoint was the first documented recurrence of any atrial arrhythmia after a 90-day blanking period. Safety endpoints included death, cerebrovascular events, and procedure-related adverse events. RESULTS: A total of 1,420 patients (paroxysmal and persistent AF) underwent PVI. With propensity score matching, 1,044 patients were analyzed in a 1:5 ratio. Over a mean follow-up of 2 years, the primary efficacy endpoint occurred in 76 (43.7%) of 174 patients with HFrEF and in 379 (43.6%) of 870 without HFrEF (HR: 1.01; 95% CI: -∞ to 1.24; P = 0.005 for noninferiority). The incidence of all-cause mortality was numerically higher in patients with HFrEF (6.3% vs 3.4%; P = 0.07), while rates of procedure-related safety events were similar between groups (2.9% vs 4.1%; P = 0.53). CONCLUSIONS: In patients with AF undergoing ablation, a PVI-only approach shows noninferior rhythm control efficacy and comparable procedural safety in patients with HFrEF compared with those without HFrEF. (Cryoballoon Pulmonary Isolation for Atrial Fibrillation With Heart Failure [POLAR-HF]; NCT04461691).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, St. Josefs-Hospital Wiesbaden, Wiesbaden Germany; Department of Medicine, Montreal Heart Institute, Université de Montréal, Montreal, Ontario, Canada.
- Department of Cardiology, St. Josefs-Hospital Wiesbaden, Wiesbaden Germany.
- Department of Medicine, Montreal Heart Institute, Université de Montréal, Montreal, Ontario, Canada; University of British Columbia, Vancouver, British Columbia, Canada.
- Vivantes Klinikum am Urban, Berlin, Germany.
- Interdisciplinary Center for Clinical Trials, University of Mainz, Mainz, Germany.
- Department of Medicine, Montreal Heart Institute, Université de Montréal, Montreal, Ontario, Canada.
Zitieren
APA
Boehmer, A. A., Rothe, M., Andrade, J. G., Wiedenmann, L., Spork, P., Schneider, K. Y., Nussbaum, E., Keim, C., Weiss, P., Dobre, B. C., Feickert, S., Ruckes, C., Dyrda, K., Kaess, B. M., Nattel, S., & Ehrlich, J. R. (2026). Pulmonary Vein Isolation Only for Atrial Fibrillation With Heart Failure (POLAR-HF). JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2025.09.041
Vancouver
Boehmer AA, Rothe M, Andrade JG, Wiedenmann L, Spork P, Schneider KY, et al. Pulmonary Vein Isolation Only for Atrial Fibrillation With Heart Failure (POLAR-HF). JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2025.09.041
BibTeX
@article{Boehmer2026,
author = {Boehmer, Andreas A and Rothe, Moritz and Andrade, Jason G and Wiedenmann, Lilli and Spork, Pascal and Schneider, Katia Y and Nussbaum, Elena and Keim, Christoph and Weiss, Peter and Dobre, Bianca C and Feickert, Sebastian and Ruckes, Christian and Dyrda, Katia and Kaess, Bernhard M and Nattel, Stanley and Ehrlich, Joachim R},
title = {Pulmonary Vein Isolation Only for Atrial Fibrillation With Heart Failure (POLAR-HF)},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
doi = {10.1016/j.jacep.2025.09.041}
}
EUVIMED