EUVIMEDEUVIMED entdecken
Crossref

Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia

Adrian M Petzl, Corentin Chaumont, Neel A Patel, Brian Otto, Lily Englander, Ramanan Kumareswaran, Timothy M Markman, David J Callans, Michael P Riley, Andres Enriquez, Matthew C Hyman, Francis E Marchlinski und 1 weitere

JACC: Clinical Electrophysiology · 2025-11 · 11 (11) · 2406-2420

DOI: 10.1016/j.jacep.2025.06.037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025-11. Verfasst von Adrian M Petzl und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pen…. Hauptthemen laut MEDLINE: Catheter Ablation, Tachycardia, Supraventricular. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Abbott Laboratories.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Identifying critical isthmuses in macro-re-entrant atrial tachycardia (MRAT) is challenging. Omnipolar Technology Near Field mapping with the Peak Frequency (PF) tool holds promise for identifying critical regions sustaining re-entry, though PF signal characteristics and the algorithm's clinical value need further exploration. OBJECTIVES: This study sought to analyze properties of PF in MRAT critical isthmuses and evaluate the value of Omnipolar Technology Near Field PF mapping in guiding ablation. METHODS: Consecutive patients undergoing MRAT ablation procedures with fully mapped circuits (using EnSite-X and HD-Grid) and termination during ablation were included. PF values were analyzed globally across the atrium and compared to the ablation termination site (within 5-mm diameter). The absolute maximum PF at and the number of ablation lesions required for termination were recorded. RESULTS: The study involved 21 MRATs (12 left, 9 right atrial) from 17 patients (age 63.9 ± 18.3 years). Termination typically required a median of 1 (Q1-Q3: 1-7) ablation lesion, with 48% terminating after the initial lesion. Maximum PF values at termination sites were significantly higher (615.2 ± 85.7 Hz) than global PF values (317.6 ± 45.4 Hz; P 530 Hz indicating maximum PF at termination sites. CONCLUSIONS: Peak frequencies at MRAT termination sites are substantially higher than global atrial PFs, supporting the potential of PF mapping as an effective tool for identifying critical isthmuses in MRAT ablation procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationTachycardia, SupraventricularHumansMiddle AgedFemaleMaleAgedElectrophysiologic Techniques, CardiacHeart AtriaAdult

Stichwörter der Autor:innen

Macro-re-entrant peak frequency mappingOmnipolar Technology Near Fieldablationcritical isthmushigh-density mappingmacro–re-entrant atrial tachycardia

Autor:innen und Institutionen

  • Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA; Cardiology Department, Rouen University Hospital, Roue…
  • Abbott Cardiovascular, Plymouth, Minnesota, USA.
  • Cardiac Electrophysiology, Division of Cardiovascular Medicine, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA. Electronic address: david.lin@pennmedicine.upenn.edu.

Förderung

  • Abbott Laboratories

Zitieren

APA

Petzl, A. M., Chaumont, C., Patel, N. A., Otto, B., Englander, L., Kumareswaran, R., Markman, T. M., Callans, D. J., Riley, M. P., Enriquez, A., Hyman, M. C., Marchlinski, F. E., & Lin, D. (2025). Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia. JACC: Clinical Electrophysiology, 11(11), 2406-2420. https://doi.org/10.1016/j.jacep.2025.06.037

Vancouver

Petzl AM, Chaumont C, Patel NA, Otto B, Englander L, Kumareswaran R, et al. Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia. JACC: Clinical Electrophysiology. 2025;11(11):2406-2420. doi:10.1016/j.jacep.2025.06.037

BibTeX
@article{Petzl2025,
  author = {Petzl, Adrian M and Chaumont, Corentin and Patel, Neel A and Otto, Brian and Englander, Lily and Kumareswaran, Ramanan and Markman, Timothy M and Callans, David J and Riley, Michael P and Enriquez, Andres and Hyman, Matthew C and Marchlinski, Francis E and Lin, David},
  title = {Peak Frequency for Characterizing and Predicting Critical Isthmus and Termination Sites in Macro-Re-Entrant Atrial Tachycardia},
  journal = {JACC: Clinical Electrophysiology},
  year = {2025},
  volume = {11},
  number = {11},
  pages = {2406--2420},
  doi = {10.1016/j.jacep.2025.06.037}
}
Kostenlos starten →