S-ICD Implantation Following TV-ICD
JACC: Clinical Electrophysiology · 2025-09 · 11 (9) · 2049-2060
DOI: 10.1016/j.jacep.2025.04.020 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift JACC: Clinical Electrophysiology, 2025-09. Verfasst von Vasileios Sousonis und 37 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Prosthesis-Related Infections. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: French Society of Cardiology, French Federation of Cardiology.
Abstract (Originalsprache)
BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) can be a viable option for patients with transvenous ICDs experiencing complications (rescue S-ICD). OBJECTIVES: This study sought to evaluate the outcomes of rescue S-ICD implantation using data from the HONEST French nationwide S-ICD cohort. METHODS: All rescue S-ICD patients were identified. Outcomes (complications, reinterventions, and mortality) were compared between rescue and de novo S-ICD patients. Subgroup analyses were performed based on the implantation indication (infective vs noninfective) and the presence of abandoned leads. RESULTS: Among 4,924 patients in the HONEST cohort, 651 underwent rescue S-ICD implantation (295 with infective indications, 244 with abandoned leads). Over a follow-up of 4.2 ± 2.2 years, complications and reinterventions were similar in rescue and de novo S-ICD patients (22.6% vs 21.0%; P = 0.35 and 8.7% vs 7.2%; P = 0.17, respectively), in infective and noninfective rescue S-ICD patients (21.6% vs 23.5%; P = 0.55 and 8.9% vs 8.6%; P = 0.90, respectively) and in patients with abandoned and extracted leads (24.3% vs 21.7%; P = 0.46 and 8.3% vs 9.0%; P = 0.77, respectively). Mortality was higher in rescue compared to de novo S-ICD patients (16.9% vs 10.2%; P < 0.001) and in rescue S-ICD patients with infective indications (29.2% vs 6.7%; P < 0.001) and extracted leads (21.9% vs 8.6%; P < 0.001), mainly due to a higher burden of comorbidities, as none of these parameters was independently associated with mortality in multivariate analyses. No S-ICD-related deaths were observed. CONCLUSIONS: Rescue S-ICD implantation is an acceptable option for patients with device-related complications. Lead abandonment in the setting of a noninfective indication appears to be safe. (S-ICD French Cohort Study [HONEST]; NCT05302115).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France.
- Department of Cardiology, University Hospital of Grenoble Alpes, Grenoble, France.
- Université de Paris, INSERM, Paris Cardiovascular Research Centre, Paris, France; Université de Brest, Laboratoire ORPHY EA 4324, Brest, France; Department of Cardiology, University Hospital of Brest, Brest, France.
- Department of Cardiology, University Hospital of Poitiers, Poitiers, France.
- Department of Cardiology, University Hospital of Lille, Lille, France.
- Intercommunal Hospital of Le Raincy Montfermeil, France.
Förderung
- French Society of Cardiology
- French Federation of Cardiology
Zitieren
APA
Sousonis, V., Jacon, P., Kerkouri, F., Garcia, R., Marquié, C., Amara, W., Anselme, F., Badenco, N., Behar, N., Belhameche, M., Bouzeman, A., Fareh, S., Guy-Moyat, B., Hermida, A., Hourdain, J., Jesel, L., Khattar, P., Khoueiry, Z., Laurent, G., …, & HONEST Study Investigators (2025). S-ICD Implantation Following TV-ICD. JACC: Clinical Electrophysiology, 11(9), 2049-2060. https://doi.org/10.1016/j.jacep.2025.04.020
Vancouver
Sousonis V, Jacon P, Kerkouri F, Garcia R, Marquié C, Amara W, et al. S-ICD Implantation Following TV-ICD. JACC: Clinical Electrophysiology. 2025;11(9):2049-2060. doi:10.1016/j.jacep.2025.04.020
BibTeX
@article{Sousonis2025,
author = {Sousonis, Vasileios and Jacon, Peggy and Kerkouri, Fawzi and Garcia, Rodrigue and Marquié, Christelle and Amara, Walid and Anselme, Fréderic and Badenco, Nicolas and Behar, Nathalie and Belhameche, Mohamed and Bouzeman, Abdeslam and Fareh, Samir and Guy-Moyat, Benoît and Hermida, Alexis and Hourdain, Jérome and Jesel, Laurence and Khattar, Pierre and Khoueiry, Ziad and Laurent, Gabriel and Manenti, Vladimir and Mechulan, Alexis and Menet, Aymeric and Milhem, Antoine and Mondoly, Pierre and Ollitrault, Pierre and Perrot, David and Peyrol, Michael and Pierre, Bertrand and Sadoul, Nicolas and Scarlatti, Didier and Taieb, Jerome and Vanesson, Claire and Winum, Pierre and Probst, Vincent and Marijon, Eloi and Defaye, Pascal and Boveda, Serge and HONEST Study Investigators, HONEST Study Investigators},
title = {S-ICD Implantation Following TV-ICD},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
volume = {11},
number = {9},
pages = {2049--2060},
doi = {10.1016/j.jacep.2025.04.020}
}
EUVIMED