Effect of Pulsed-Field Ablation on Human Coronary Arteries
JACC: Clinical Electrophysiology · 2025-07 · 11 (7) · 1478-1488
DOI: 10.1016/j.jacep.2025.03.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025-07. Verfasst von Mark T K Tam und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Coronary Vessels, Catheter Ablation, Atrial Flutter. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Pulsed-field ablation (PFA) is known to cause acute coronary spasm. Whether this translates into long-term coronary artery stenosis is unknown. OBJECTIVES: This study sought to evaluate changes in coronary artery after PFA for atrial flutter. METHODS: After pulmonary vein isolation with PFA (Farapulse; Boston Scientific), patients undergoing ablation of the mitral isthmus (MI) or cavotricuspid isthmus (CTI) were included. They underwent coronary angiography and optical coherence tomography (OCT) before and immediately after ablation. Bolus intracoronary nitroglycerine was given before and throughout ablation. Three months after ablation, patients underwent repeated OCT. RESULTS: A total of 21 patients were included. 1 patient did not undergo PFA owing to the incidental finding of a critical coronary lesion in close proximity to the area to be ablated. Another patient defaulted postprocedure imaging follow-up. 19 patients had paired imaging data, in 20 coronary vessels (18 right coronary and 2 left circumflex arteries). At the ablation site, at 3 months, vascular wall area increased by a median of 0.40 mm2 (Q1-Q3: 0.13-0.71 mm2; P < 0.01), or 17.1% (Q1-Q3: 8.6%-31.0%). The median reduction in the luminal area was 0.70 mm2 (Q1-Q3: 0.18-1.30 mm2; P < 0.01), or 10.1% (Q1-Q3: 4.7%-16.2%). These changes were not observed in a predetermined reference site remote from the ablation target. CONCLUSIONS: PFA of the CTI and MI is associated with acute spasm, and mild narrowing of the coronary arteries at 3 months. Although intracoronary vasodilator therapy may prevent or treat acute spasm, the risk of arterial stenosis remains, calling for heightened vigilance and long-term follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
- Division of Cardiology, Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong. Electronic address: bryan.yan@cuhk.edu.hk.
Zitieren
APA
Tam, M. T. K., Chan, J. Y. S., Chan, C. P., Wu, E. B., Lai, A., Au, A. C. K., Chi, W. K., Tan, G., & Yan, B. P. (2025). Effect of Pulsed-Field Ablation on Human Coronary Arteries. JACC: Clinical Electrophysiology, 11(7), 1478-1488. https://doi.org/10.1016/j.jacep.2025.03.014
Vancouver
Tam MTK, Chan JYS, Chan CP, Wu EB, Lai A, Au ACK, et al. Effect of Pulsed-Field Ablation on Human Coronary Arteries. JACC: Clinical Electrophysiology. 2025;11(7):1478-1488. doi:10.1016/j.jacep.2025.03.014
BibTeX
@article{Tam2025,
author = {Tam, Mark T K and Chan, Joseph Y S and Chan, Chin Pang and Wu, Eugene B and Lai, Angel and Au, Alex C K and Chi, Wai Kin and Tan, GuangMing and Yan, Bryan P},
title = {Effect of Pulsed-Field Ablation on Human Coronary Arteries},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
volume = {11},
number = {7},
pages = {1478--1488},
doi = {10.1016/j.jacep.2025.03.014}
}