EUVIMEDEUVIMED entdecken
Crossref

Predictive Value of Right Ventricular Sensing During Cardiac Device Implantation to Diagnose Cardiac Amyloidosis

David Hamon, Rosanna Landes, Thibaut Moulin, Jocelyn Inamo, Carole Maupain, Silvia Oghina, Mounira Kharoubi, Françoise Hidden-Lucet, Estelle Gandjbakhch, Emmanuel Teiger, Thibaud Damy, Nicolas Lellouche

JACC: Clinical Electrophysiology · 2025

DOI: 10.1016/j.jacep.2024.09.041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025. Verfasst von David Hamon und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Creteil, France; Groupe de Recherche Clinique, Amy…. Hauptthemen laut MEDLINE: Amyloidosis, Heart Ventricles, Cardiomyopathies. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Cardiac amyloidosis (CA) is an underdiagnosed disease, often presenting with electrical conduction abnormalities or ventricular arrhythmias, prompting implantation of cardiac implantable electrical devices (CIEDs). OBJECTIVES: This study sought to evaluate the performance of right ventricular sensing (RVSens) during implantation of CIEDs in patients presenting with increased left ventricular (LV) wall thicknesses (ILVWT) and preserved LV function to predict the diagnosis of CA. METHODS: All consecutive patients with ILVWT (maximal LV wall thickness ≥12 mm), preserved LV function and no significant aortic stenosis who underwent implantation of CIEDs at 2 French referral centers for rare and inheritable cardiac diseases were retrospectively evaluated. Clinical history, imaging, biological data, histologic data, and pacing lead parameters at the time of implantation were collected. Diagnostic categorization of ILVWT (CA, sarcomeric hypertrophic cardiomyopathy, or hypertensive heart disease) was determined according to guidelines. RESULTS: We included 218 patients with ILVWT, of which 150 had CA and 68 had sarcomeric hypertrophic cardiomyopathy or hypertensive heart disease. Ten patients (4.6%) had their device implanted before ILVWT diagnosis, 131 (60.1%) had their device implanted during the same hospitalization, and 77 (35.3%) in a subsequent hospitalization. An RVSens ≤11 mV was independently associated with CA diagnosis with a sensitivity of 84% and a specificity of 79.4% (AUC: 0.878). CONCLUSIONS: In patients with ILVWT, a relatively low RVSens (≤11 mV) during device implantation was independently associated with CA diagnosis, prompting further evaluation to rule out CA if the diagnosis is uncertain.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmyloidosisHeart VentriclesCardiomyopathiesHumansMaleFemaleRetrospective StudiesMiddle AgedAgedPredictive Value of TestsDefibrillators, ImplantableEchocardiographyAdult

Stichwörter der Autor:innen

cardiac amyloidosiscardiac devicescardiac hypertrophyright ventricular sensing

Autor:innen und Institutionen

  • Department of Cardiology, University Hospital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Creteil, France; Groupe de Recherche Clinique, Amyloid Research Institute and Clinical Epidemiology of Ageing, Institut…
  • Department of Cardiology, University Hospital of Martinique, Martinique, France.
  • Division of Cardiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA.
  • Department of Cardiology, University Hospital Pitié-Salpétrière, Assistance Publique-Hôpitaux de Paris, Paris, France.

Zitieren

APA

Hamon, D., Landes, R., Moulin, T., Inamo, J., Maupain, C., Oghina, S., Kharoubi, M., Hidden-Lucet, F., Gandjbakhch, E., Teiger, E., Damy, T., & Lellouche, N. (2025). Predictive Value of Right Ventricular Sensing During Cardiac Device Implantation to Diagnose Cardiac Amyloidosis. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2024.09.041

Vancouver

Hamon D, Landes R, Moulin T, Inamo J, Maupain C, Oghina S, et al. Predictive Value of Right Ventricular Sensing During Cardiac Device Implantation to Diagnose Cardiac Amyloidosis. JACC: Clinical Electrophysiology. 2025. doi:10.1016/j.jacep.2024.09.041

BibTeX
@article{Hamon2025,
  author = {Hamon, David and Landes, Rosanna and Moulin, Thibaut and Inamo, Jocelyn and Maupain, Carole and Oghina, Silvia and Kharoubi, Mounira and Hidden-Lucet, Françoise and Gandjbakhch, Estelle and Teiger, Emmanuel and Damy, Thibaud and Lellouche, Nicolas},
  title = {Predictive Value of Right Ventricular Sensing During Cardiac Device Implantation to Diagnose Cardiac Amyloidosis},
  journal = {JACC: Clinical Electrophysiology},
  year = {2025},
  doi = {10.1016/j.jacep.2024.09.041}
}
Kostenlos starten →