EUVIMEDEUVIMED entdecken
Crossref

Pulmonary Veins Function as Echo Chambers in Persistent Atrial Fibrillation

Shu Meng, Ahmed M Al-Kaisey, Ramanathan Parameswaran, Nicholas Sunderland, David M Budgett, Peter M Kistler, Bruce H Smaill, Jonathan M Kalman

JACC: Clinical Electrophysiology · 2024

DOI: 10.1016/j.jacep.2024.03.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024. Verfasst von Shu Meng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Auckland Bioengineering Institute, University of Auckland, Auckland New Zealand. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although the substrate in persistent atrial fibrillation (PeAF) is not limited to the pulmonary veins (PVs), PV isolation (PVI) remains the cornerstone ablation strategy. OBJECTIVES: The aim of this study was to describe the mechanism of outgoing wavefronts (WFs) originating in the PV sleeves during PeAF. METHODS: Eleven patients presenting for first-time PeAF ablation were recruited (mean age 63.1 ± 10.9 years, 91% men). A 64-electrode catheter (Constellation; 38 mm) was positioned within the PV under fluoroscopic guidance. An inverse mapping technique was used to reconstruct unipolar atrial electrograms on the PV surface, and the resulting phase maps were used to identify incoming and outgoing WFs at the PV junction and to classify focal and re-entrant activity within the PV sleeves. RESULTS: During PeAF, the PVs gave rise to outgoing WFs with a frequency of 3.7 s-1 (Q1-Q3: 3.4-5.4 s-1) compared with 3.6 s-1 (Q1-Q3: 2.8-4.2 s-1) for incoming WFs. Circuitous macroscopic re-entry was the dominant mechanism driving outgoing WFs (frequency of re-entry 2.7 s-1 [Q1-Q3: 2.0-3.3 s-1] compared with focal activity 1.4 s-1 [Q1-Q3: 1.1-1.5 s-1]; P 1 in 6 of 11 PVs. CONCLUSIONS: Electric activity generated by PV sleeves during PeAF is due mainly to circuitous re-entry initiated by incoming waves, frequently with R > 1. That is, the PVs act less as drivers of atrial fibrillation than as "echo chambers" that sustain and amplify fibrillatory activity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsCatheter AblationHumansMiddle AgedFemaleMaleAgedElectrophysiologic Techniques, Cardiac

Stichwörter der Autor:innen

3-dimensionalatrial fibrillationfibrillatory driversintracardiac electric mappingphase mapping

Autor:innen und Institutionen

  • Auckland Bioengineering Institute, University of Auckland, Auckland New Zealand.
  • Department of Medicine, University of Melbourne, Melbourne, Australia; Department of Cardiology, Royal Melbourne Hospital, Melbourne, Australia.
  • Bristol Heart Institute, Bristol University, Bristol, United Kingdom.
  • Department of Medicine, University of Melbourne, Melbourne, Australia; Heart Centre, Alfred Hospital, Melbourne, Australia; Baker IDI Heart & Diabetes Institute, Melbourne, Australia.
  • Department of Medicine, University of Melbourne, Melbourne, Australia; Department of Cardiology, Royal Melbourne Hospital, Melbourne, Australia; Baker IDI Heart & Diabetes Institute, Melbourne, Australia. Electronic add…

Zitieren

APA

Meng, S., Al-Kaisey, A. M., Parameswaran, R., Sunderland, N., Budgett, D. M., Kistler, P. M., Smaill, B. H., & Kalman, J. M. (2024). Pulmonary Veins Function as Echo Chambers in Persistent Atrial Fibrillation. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2024.03.025

Vancouver

Meng S, Al-Kaisey AM, Parameswaran R, Sunderland N, Budgett DM, Kistler PM, et al. Pulmonary Veins Function as Echo Chambers in Persistent Atrial Fibrillation. JACC: Clinical Electrophysiology. 2024. doi:10.1016/j.jacep.2024.03.025

BibTeX
@article{Meng2024,
  author = {Meng, Shu and Al-Kaisey, Ahmed M and Parameswaran, Ramanathan and Sunderland, Nicholas and Budgett, David M and Kistler, Peter M and Smaill, Bruce H and Kalman, Jonathan M},
  title = {Pulmonary Veins Function as Echo Chambers in Persistent Atrial Fibrillation},
  journal = {JACC: Clinical Electrophysiology},
  year = {2024},
  doi = {10.1016/j.jacep.2024.03.025}
}
Kostenlos starten →