Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation
JACC: Clinical Electrophysiology · 2024-05 · 10 (5) · 885-896
DOI: 10.1016/j.jacep.2023.12.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024-05. Verfasst von Yury Malyshev und 12 weiteren Autor:innen. Beteiligte Einrichtung: Icahn School of Medicine at Mount Sinai, New York, New York, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Nitroglycerin, Coronary Vasospasm, Catheter Ablation. Die Arbeit wurde bisher 113-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Boston Scientific Corp.
Abstract (Originalsprache)
BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Icahn School of Medicine at Mount Sinai, New York, New York, USA.
- Homolka Hospital, Prague, Czech Republic.
- Farapulse-Boston Scientific, Inc, Menlo Park, California, USA.
- Icahn School of Medicine at Mount Sinai, New York, New York, USA; Homolka Hospital, Prague, Czech Republic. Electronic address: vivek.reddy@mountsinai.org.
Förderung
- Boston Scientific Corp
Zitieren
APA
Malyshev, Y., Neuzil, P., Petru, J., Funasako, M., Hala, P., Kopriva, K., Schneider, C., Achyutha, A., Vanderper, A., Musikantow, D., Turagam, M., Dukkipati, S. R., & Reddy, V. Y. (2024). Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation. JACC: Clinical Electrophysiology, 10(5), 885-896. https://doi.org/10.1016/j.jacep.2023.12.015
Vancouver
Malyshev Y, Neuzil P, Petru J, Funasako M, Hala P, Kopriva K, et al. Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation. JACC: Clinical Electrophysiology. 2024;10(5):885-896. doi:10.1016/j.jacep.2023.12.015
BibTeX
@article{Malyshev2024,
author = {Malyshev, Yury and Neuzil, Petr and Petru, Jan and Funasako, Moritoshi and Hala, Pavel and Kopriva, Karel and Schneider, Christopher and Achyutha, Anitha and Vanderper, Annelies and Musikantow, Daniel and Turagam, Mohit and Dukkipati, Srinivas R and Reddy, Vivek Y},
title = {Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation},
journal = {JACC: Clinical Electrophysiology},
year = {2024},
volume = {10},
number = {5},
pages = {885--896},
doi = {10.1016/j.jacep.2023.12.015}
}
EUVIMED