Detecting Paroxysmal Atrial Fibrillation From an Electrocardiogram in Sinus Rhythm
JACC: Clinical Electrophysiology · 2023-08 · 9 (8) · 1771-1782
DOI: 10.1016/j.jacep.2023.04.008 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2023-08. Verfasst von Henri Gruwez und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Hospital East-Limburg, Genk, Belgium; Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium; Doctora…. Hauptthemen laut MEDLINE: Atrial Fibrillation. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek Vlaanderen.
Abstract (Originalsprache)
BACKGROUND: Atrial fibrillation (AF) may occur asymptomatically and can be diagnosed only with electrocardiography (ECG) while the arrhythmia is present. OBJECTIVES: The aim of this study was to independently validate the approach of using artificial intelligence (AI) to identify underlying paroxysmal AF from a 12-lead ECG in sinus rhythm (SR). METHODS: An AI algorithm was trained to identify patients with underlying paroxysmal AF, using electrocardiographic data from all in- and outpatients from a single center with at least 1 ECG in SR. For patients without AF, all ECGs in SR were included. For patients with AF, all ECGs in SR starting 31 days before the first AF event were included. The patients were randomly allocated to training, internal validation, and testing datasets in a 7:1:2 ratio. In a secondary analysis, the AF prevalence of the testing group was modified. Additionally, the performance of the algorithm was validated at an external hospital. RESULTS: The dataset consisted of 494,042 ECGs in SR from 142,310 patients. Testing the model on the first ECG of each patient (AF prevalence 9.0%) resulted in accuracy of 78.1% (95% CI: 77.6%-78.5%), area under the receiver-operating characteristic curve of 0.87 (95% CI: 0.86-0.87), and area under the precision recall curve (AUPRC) of 0.48 (95% CI: 0.46-0.50). In a low-risk group (AF prevalence 3%), the AUPRC decreased to 0.21 (95% CI: 0.18-0.24). In a high-risk group (AF prevalence 30%), the AUPRC increased to 0.76 (95% CI: 0.75-0.78). This performance was robust when validated in an external hospital. CONCLUSIONS: The approach of using an AI-enabled electrocardiographic algorithm for the identification of patients with underlying paroxysmal AF from ECGs in SR was independently validated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Hospital East-Limburg, Genk, Belgium; Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium; Doctoral School of Medicine and Life Science, Hasselt University, Hasselt, Be…
- Data Science Department, Hospital East-Limburg, Genk, Belgium.
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.
- Centre for Cardiovascular Diseases, University Hospital Brussels, Jette, Belgium; Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.
- Department of Cardiology, Hospital East-Limburg, Genk, Belgium; Doctoral School of Medicine and Life Science, Hasselt University, Hasselt, Belgium.
- LCRC, Mobile Health Unit, Hasselt University, Hasselt, Belgium; Future Health Department, Hospital East-Limburg, Genk, Belgium.
Förderung
- Fonds Wetenschappelijk Onderzoek Vlaanderen
Zitieren
APA
Gruwez, H., Barthels, M., Haemers, P., Verbrugge, F. H., Dhont, S., Meekers, E., Wouters, F., Nuyens, D., Pison, L., Vandervoort, P., & Pierlet, N. (2023). Detecting Paroxysmal Atrial Fibrillation From an Electrocardiogram in Sinus Rhythm. JACC: Clinical Electrophysiology, 9(8), 1771-1782. https://doi.org/10.1016/j.jacep.2023.04.008
Vancouver
Gruwez H, Barthels M, Haemers P, Verbrugge FH, Dhont S, Meekers E, et al. Detecting Paroxysmal Atrial Fibrillation From an Electrocardiogram in Sinus Rhythm. JACC: Clinical Electrophysiology. 2023;9(8):1771-1782. doi:10.1016/j.jacep.2023.04.008
BibTeX
@article{Gruwez2023,
author = {Gruwez, Henri and Barthels, Myrte and Haemers, Peter and Verbrugge, Frederik H and Dhont, Sebastiaan and Meekers, Evelyne and Wouters, Femke and Nuyens, Dieter and Pison, Laurent and Vandervoort, Pieter and Pierlet, Noëlla},
title = {Detecting Paroxysmal Atrial Fibrillation From an Electrocardiogram in Sinus Rhythm},
journal = {JACC: Clinical Electrophysiology},
year = {2023},
volume = {9},
number = {8},
pages = {1771--1782},
doi = {10.1016/j.jacep.2023.04.008}
}
EUVIMED