Left Bundle Branch Area Defibrillator (LBBAD)
JACC: Clinical Electrophysiology · 2023-05 · 9 (5) · 620-627
DOI: 10.1016/j.jacep.2023.01.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2023-05. Verfasst von Wim L H Huybrechts und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Antwerp, Edegem, Belgium; Department GENCOR-Heart Rhythm Disorders, University of Antwerp, Antwerp, Bel…. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Ventricular Septum. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Left bundle branch area (LBBA) pacing is a promising pacing technique. LBBA implantable cardioverter-defibrillator (ICD) lead implantation reduces the number of leads in patients with both pacing and ICD indications, reducing cost and potentially increasing safety. LBBA positioning of ICD leads has not previously been described. OBJECTIVES: The goal of this study was to evaluate the safety and feasibility of implanting an LBBA ICD lead. METHODS: This prospective, single-center, feasibility study was conducted in patients with an ICD indication. LBBA ICD lead implantation was attempted. Acute pacing parameters and paced electrocardiography data were collected, and defibrillation testing was performed. RESULTS: LBBA defibrillator (LBBAD) implantation was attempted in 5 patients (mean age 57 ± 16.5 years; 20% female) and achieved in 3 (60%). Mean procedural and fluoroscopy duration were 170.0 ± 17.3 minutes and 28.8 ± 16.1 minutes, respectively. Left bundle capture was achieved in 2 patients (66%) and left septal capture in 1 patient. LBBA pacing exhibited a mean QRS duration and V6 R-wave peak time of 121.3 ± 8.3 milliseconds and 86.1 ± 10.0 milliseconds. In all 3 patients, defibrillation testing was successful with mean time to adequate shock delivery of 8.6 ± 2.6 seconds. Acute LBBA pacing threshold and R-wave amplitudes were 0.80 ± 0.60 V at 0.4 milliseconds and 7.0 ± 2.7 mV. No LBBA lead-related complications occurred. CONCLUSIONS: This first-in-human evaluation showed the feasibility of LBBAD implantation in a small cohort of patients. With current tools, implantation remains complex and time-consuming. Considering the feasibility reported and the potential benefits, further technological development in this field is warranted with evaluation of long-term safety and performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Hospital Antwerp, Edegem, Belgium; Department GENCOR-Heart Rhythm Disorders, University of Antwerp, Antwerp, Belgium. Electronic address: wim.huybrechts@uza.be.
- Department of Cardiology, University Hospital Antwerp, Edegem, Belgium. Electronic address: https://twitter.com/Mbergonti.
- Department of Cardiology, University Hospital Antwerp, Edegem, Belgium; Department GENCOR-Heart Rhythm Disorders, University of Antwerp, Antwerp, Belgium.
- Department of Cardiology, University Hospital Antwerp, Edegem, Belgium.
- Department of Anesthesiology, University Hospital Antwerp, Edegem, Belgium.
- Department of Cardiology, AZ KLINA, Brasschaat, Belgium.
Zitieren
APA
Huybrechts, W. L. H., Bergonti, M., Saenen, J. B., Miljoen, H., Van Leuven, O., Van Assche, L., Van Herck, P., Wittock, A., De Cleen, D., Sarkozy, A., & Heidbüchel, H. (2023). Left Bundle Branch Area Defibrillator (LBBAD). JACC: Clinical Electrophysiology, 9(5), 620-627. https://doi.org/10.1016/j.jacep.2023.01.006
Vancouver
Huybrechts WLH, Bergonti M, Saenen JB, Miljoen H, Van Leuven O, Van Assche L, et al. Left Bundle Branch Area Defibrillator (LBBAD). JACC: Clinical Electrophysiology. 2023;9(5):620-627. doi:10.1016/j.jacep.2023.01.006
BibTeX
@article{Huybrechts2023,
author = {Huybrechts, Wim L H and Bergonti, Marco and Saenen, Johan B and Miljoen, Hielko and Van Leuven, Olivier and Van Assche, Lauranne and Van Herck, Paul and Wittock, Anouk and De Cleen, Dieter and Sarkozy, Andrea and Heidbüchel, Hein},
title = {Left Bundle Branch Area Defibrillator (LBBAD)},
journal = {JACC: Clinical Electrophysiology},
year = {2023},
volume = {9},
number = {5},
pages = {620--627},
doi = {10.1016/j.jacep.2023.01.006}
}
EUVIMED