Fachartikel in der Zeitschrift JACC: Basic to Translational Science, 2025-07. Verfasst von Kevin M Blum und 14 weiteren Autor:innen. Beteiligte Einrichtung: Center for Regenerative Medicine, The Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Biomedica…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, US Department of Defense, NHLBI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tissue-engineered vascular grafts (TEVGs) offer promising advancements in treating congenital heart disease by enabling the creation of autologous tissue for complex cardiac repairs. Our approach involves implanting biodegradable scaffolds seeded with autologous cells that remodel into functional neovessels. To understand better the factors guiding neovessel formation, we evaluated 50 ovine thoracic TEVGs using angiography at 1 and 6 weeks postimplantation. Nondimensionalization accounted for anatomical differences between animals and identified hemodynamics and surgical sizing as potential driving factors. Regression analysis revealed that narrowing at the inflow anastomosis and graft oversizing correlated significantly with stenosis development. Computational fluid dynamics showed that these factors influenced wall shear stress and flow patterns, contributing to neovessel narrowing. Comparisons with clinical trial data from Fontan conduits supported these findings, emphasizing that matching graft size to the native inflow vessel can reduce stenosis and enhance TEVG performance.

Schlagwörter

Stichwörter der Autor:innen

computational fluid dynamicsoversizingstenosistissue engineered vascular graft

Autor:innen und Institutionen

  • Center for Regenerative Medicine, The Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA.
  • Center for Regenerative Medicine, The Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Molecular, Cellular, and Developmental Biology, The Ohio State University, Colu…
  • Department of Pediatrics and Bioengineering, Stanford University, Stanford, California, USA; Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
  • Center for Regenerative Medicine, The Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, Ohio, USA.
  • Center for Regenerative Medicine, The Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, Ohio, USA; Department of Pediatric Cardiology, Nationwide Children's Hospital, Columbus, Ohio, USA.
  • Department of Pediatric Cardiology, Nationwide Children's Hospital, Columbus, Ohio, USA.

Förderung

  • NHLBI NIH HHS
  • US Department of Defense
  • NHLBI

Zitieren

APA

Blum, K. M., Turner, M. E., Schwarz, E. L., Best, C. A., Kelly, J. M., Yates, A. R., Hor, K. N., Matsuzaki, Y., Drews, J. D., Zakko, J., Shah, K., Shinoka, T., Humphrey, J. D., Marsden, A. L., & Breuer, C. K. (2025). Oversized Conduits Predict Stenosis in Tissue Engineered Vascular Grafts. JACC: Basic to Translational Science, 10(7), 101248. https://doi.org/10.1016/j.jacbts.2025.02.008

Vancouver

Blum KM, Turner ME, Schwarz EL, Best CA, Kelly JM, Yates AR, et al. Oversized Conduits Predict Stenosis in Tissue Engineered Vascular Grafts. JACC: Basic to Translational Science. 2025;10(7):101248. doi:10.1016/j.jacbts.2025.02.008

BibTeX
@article{Blum2025,
  author = {Blum, Kevin M and Turner, Mackenzie E and Schwarz, Erica L and Best, Cameron A and Kelly, John M and Yates, Andrew R and Hor, Kan N and Matsuzaki, Yuichi and Drews, Joseph D and Zakko, Jason and Shah, Kejal and Shinoka, Toshiharu and Humphrey, Jay D and Marsden, Alison L and Breuer, Christopher K},
  title = {Oversized Conduits Predict Stenosis in Tissue Engineered Vascular Grafts},
  journal = {JACC: Basic to Translational Science},
  year = {2025},
  volume = {10},
  number = {7},
  pages = {101248},
  doi = {10.1016/j.jacbts.2025.02.008}
}
Kostenlos starten →