Optical coherence tomography-measured blood vessel characteristics of port-wine birthmarks by depth: A cross-sectional study
Journal of the American Academy of Dermatology · 2024-11 · 91 (5) · 848-854
DOI: 10.1016/j.jaad.2024.06.082 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Journal of the American Academy of Dermatology, 2024-11. Verfasst von Rachel Ann Elsanadi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, University of California, Irvine, Irvine, California. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Port-Wine Stain. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAMS NIH HHS, Institute for Clinical and Translational Science, University of California, Irvine.
Abstract (Originalsprache)
BACKGROUND: Port-Wine Birthmarks (PWB) are congenital capillary malformations requiring multiple treatments. Optical coherence tomography (OCT), a noninvasive imaging technique, characterizes vessels in cutaneous vascular lesions, including PWBs. OBJECTIVE: To assess variability in blood vessel characteristics within and between individual PWBs. METHODS: OCT was used to measure blood vessel density (%) and modal vessel diameter (micrometers) at increments of 0.05 mm from the skin surface to a depth of 0.50 mm at several adjacent spots of single PWBs in this cross-sectional study. Average ratios of vessel density and diameter in affected to control skin were obtained for each PWB by averaging data for all spots within a lesion. Statistical analysis was performed with a linear mixed effects model using SPSS software (IBM Corporation). RESULTS: There was great variability in vessel density and diameter within and between PWBs. Depths where average ratios of vessel density were consistently greater in affected to control skin were shallow, between 0.15 mm and 0.2 mm deep from the skin surface. LIMITATIONS: Small sample size and device's inability to measure diameters smaller than 20 micrometers. CONCLUSION: There is variability in vessel density and diameter within and between PWBs. Individualized treatment planning guided by OCT mapping should be studied further.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dermatology, University of California, Irvine, Irvine, California.
- Institute for Clinical and Translational Science, University of California, Irvine, Irvine, California.
- Beckman Laser Institute, University of California, Irvine, Irvine, California.
- Department of Dermatology, University of California, Irvine, Irvine, California; Beckman Laser Institute, University of California, Irvine, Irvine, California. Electronic address: KMKelly@hs.uci.edu.
Förderung
- NIAMS NIH HHS
- Institute for Clinical and Translational Science, University of California, Irvine
Zitieren
APA
Elsanadi, R. A., Messele, F., Lee, J., Choi, B., & Kelly, K. M. (2024). Optical coherence tomography-measured blood vessel characteristics of port-wine birthmarks by depth: A cross-sectional study. Journal of the American Academy of Dermatology, 91(5), 848-854. https://doi.org/10.1016/j.jaad.2024.06.082
Vancouver
Elsanadi RA, Messele F, Lee J, Choi B, Kelly KM. Optical coherence tomography-measured blood vessel characteristics of port-wine birthmarks by depth: A cross-sectional study. Journal of the American Academy of Dermatology. 2024;91(5):848-854. doi:10.1016/j.jaad.2024.06.082
BibTeX
@article{Elsanadi2024,
author = {Elsanadi, Rachel Ann and Messele, Feben and Lee, Jaylen and Choi, Bernard and Kelly, Kristen M},
title = {Optical coherence tomography-measured blood vessel characteristics of port-wine birthmarks by depth: A cross-sectional study},
journal = {Journal of the American Academy of Dermatology},
year = {2024},
volume = {91},
number = {5},
pages = {848--854},
doi = {10.1016/j.jaad.2024.06.082}
}
EUVIMED