EUVIMEDEUVIMED entdecken
Crossref

Adaptive neural fault-tolerant prescribed performance control of a rehabilitation exoskeleton for lower limb passive training

Yong Yang, Deqing Huang, Lei Ma, Xia Liu, Yanan Li

ISA Transactions · 2024-08 · 151 · 143-152

DOI: 10.1016/j.isatra.2024.06.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ISA Transactions, 2024-08. Verfasst von Yong Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering and Electronic Information, Xihua University, Chengdu, 610039, China. Hauptthemen laut MEDLINE: Exoskeleton Device, Neural Networks, Computer, Lower Extremity, Algorithms. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Natural Science Foundation of Sichuan Province, Sichuan Province Department of Science and Technology, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article studies the passive tracking problem of a wearable exoskeleton for lower limb rehabilitation therapy in the face of unmodeled dynamics, interactive friction, disturbance, prescribed performance constraints, and actuator faults. Adaptive neural networks and a smooth performance function are incorporated to establish a novel fault-tolerant tracking scheme, which can not only compensate for the nonlinear uncertainties and disturbance, but also handle the actuator fault with guaranteed tracking performance. A state feedback controller is presented by using the full state information and an output feedback controller is developed when the angular velocity is unavailable. The differential explosion issue of the backstepping technique is resolved by constructing a first-order filter and the unmeasurable velocity is estimated by a nonlinear observer. Semiglobal uniform boundedness stabilities of the exoskeleton system are proved via the Lyapunov direct method. The tracking performances of the designed control approaches are tested by comparative simulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exoskeleton DeviceNeural Networks, ComputerLower ExtremityAlgorithmsComputer SimulationHumansFeedbackEquipment DesignNonlinear Dynamics

Stichwörter der Autor:innen

Fault-tolerant trackingPassive rehabilitation therapyPrescribed performanceRehabilitation exoskeleton

Autor:innen und Institutionen

  • School of Electrical Engineering and Electronic Information, Xihua University, Chengdu, 610039, China.
  • School of Electrical Engineering, Southwest Jiaotong University, Chengdu, 610031, China.
  • School of Engineering and Informatics, University of Sussex, Brighton, BN1 9RH, UK. Electronic address: yl557@sussex.ac.uk.

Förderung

  • Natural Science Foundation of Sichuan Province
  • Sichuan Province Department of Science and Technology
  • National Natural Science Foundation of China

Zitieren

APA

Yang, Y., Huang, D., Ma, L., Liu, X., & Li, Y. (2024). Adaptive neural fault-tolerant prescribed performance control of a rehabilitation exoskeleton for lower limb passive training. ISA Transactions, 151, 143-152. https://doi.org/10.1016/j.isatra.2024.06.001

Vancouver

Yang Y, Huang D, Ma L, Liu X, Li Y. Adaptive neural fault-tolerant prescribed performance control of a rehabilitation exoskeleton for lower limb passive training. ISA Transactions. 2024;151:143-152. doi:10.1016/j.isatra.2024.06.001

BibTeX
@article{Yang2024,
  author = {Yang, Yong and Huang, Deqing and Ma, Lei and Liu, Xia and Li, Yanan},
  title = {Adaptive neural fault-tolerant prescribed performance control of a rehabilitation exoskeleton for lower limb passive training},
  journal = {ISA Transactions},
  year = {2024},
  volume = {151},
  pages = {143--152},
  doi = {10.1016/j.isatra.2024.06.001}
}
Kostenlos starten →