Computed torque control and force analysis for mechanical leg with variable rotation axis powered by servo pneumatic muscle
ISA Transactions · 2023-09 · 140 · 385-401
DOI: 10.1016/j.isatra.2023.06.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift ISA Transactions, 2023-09. Verfasst von Binrui Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou 310018, China. Hauptthemen laut MEDLINE: Knee Joint, Gait. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Key Scientific Instrument and Equipment Development Projects of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
It is difficult for a humanoid leg driven by two groups of antagonistic pneumatic muscles (PMs) to achieve a flexible humanoid gait, and its inherent strong coupling nonlinear characteristics make it hard to achieve good tracking performance in a large range of motion. Therefore, a four-bar linkage bionic knee joint structure with a variable axis and a double closed-loop servo position control strategy based on computed torque control are designed to improve anthropomorphic characteristics and the dynamic performance of the bionic mechanical leg powered by servo pneumatic muscle (SPM). Firstly, the relationship between the joint torque, the initial jump angle and the bounce height of the mechanical leg is established, and then we design a double-joint PM bionic mechanical leg containing a four-bar linkage mechanism of the knee joint. Secondly, a cascade position control strategy is developed, which consists of the outer position loop and the inner contraction force loop, and the mapping relationship is designed between joint torque and antagonistic PM contraction force. Finally, we further project bounce action timing of mechanical leg to realize the periodic jumping movement of the mechanical leg, and simulation and physical experiments of the real-style machine platform have been provided to demonstrate the effectiveness of the designed SPM controller.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou 310018, China.
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada.
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21211, USA.
- College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou 310018, China. Electronic address: 13488950521@163.com.
Förderung
- National Key Scientific Instrument and Equipment Development Projects of China
- National Key Research and Development Program of China
Zitieren
APA
Wang, B., Wang, Y., Huang, J., Zeng, Y., Liu, X., & Zhou, K. (2023). Computed torque control and force analysis for mechanical leg with variable rotation axis powered by servo pneumatic muscle. ISA Transactions, 140, 385-401. https://doi.org/10.1016/j.isatra.2023.06.014
Vancouver
Wang B, Wang Y, Huang J, Zeng Y, Liu X, Zhou K. Computed torque control and force analysis for mechanical leg with variable rotation axis powered by servo pneumatic muscle. ISA Transactions. 2023;140:385-401. doi:10.1016/j.isatra.2023.06.014
BibTeX
@article{Wang2023,
author = {Wang, Binrui and Wang, Youcao and Huang, Jiqing and Zeng, Yuxin and Liu, Xiaolong and Zhou, Kun},
title = {Computed torque control and force analysis for mechanical leg with variable rotation axis powered by servo pneumatic muscle},
journal = {ISA Transactions},
year = {2023},
volume = {140},
pages = {385--401},
doi = {10.1016/j.isatra.2023.06.014}
}
EUVIMED