EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of device-based and bioelectrical impedance methods for volume status assessment in heart failure patients with cardiac implantable electronic devices (CIED vs. BIA fluid assessment in heart failure)

Sedat Altıntepe, Fatih Gülçebi, Ahmet Özderya, Nurel Bellur, Ezgi Kalaycıoğlu

Indian Pacing and Electrophysiology Journal · 2026-09 · 26 (5) · 516-522

DOI: 10.1016/j.ipej.2026.08.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Pacing and Electrophysiology Journal, 2026-09. Verfasst von Sedat Altıntepe und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Vakfıkebir State Hospital, Trabzon, Türkiye. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate assessment of volume status is essential in heart failure (HF). This study evaluated the association between cardiac implantable electronic device (CIED)-derived fluid monitoring and bioelectrical impedance analysis (BIA) for systemic volume assessment. METHODS: In this prospective cross-sectional study, 57 patients with HF carrying implantable cardioverter-defibrillators or cardiac resynchronization therapy devices with intrathoracic impedance-based fluid monitoring were enrolled. Patients were classified according to the presence of device-detected fluid alerts. Body composition and total body water (TBW) percentage were assessed by BIA (Tanita). Clinical, laboratory, echocardiographic, and device-derived data were compared. Logistic regression identified variables independently associated with fluid alerts. RESULTS: Patients with device-detected fluid alerts had higher TBW and lower body fat percentages than those without alerts (both p < 0.001). TBW showed a strong positive correlation with device-detected fluid alerts (r = 0.675, p < 0.001). A TBW threshold of 57.15% predicted fluid alerts with 80% sensitivity and 80% specificity (AUC 0.938, 95% CI 0.856-0.999; p < 0.001). Patients with fluid alerts also demonstrated more pronounced echocardiographic signs of right-sided congestion. In multivariable analysis, TBW remained the only independent predictor of device-detected fluid alerts (OR 1.33, 95% CI 1.07-1.66; p = 0.011). CONCLUSION: BIA-derived TBW was strongly associated with device-detected fluid alerts and may serve as a practical complementary method for systemic volume assessment, particularly when device-based fluid monitoring is unavailable.

Schlagwörter

Stichwörter der Autor:innen

Bioelectrical impedance analysisCardiac implantable electronic devicesHeart failureIntrathoracic impedanceVolume status

Autor:innen und Institutionen

  • Department of Cardiology, Vakfıkebir State Hospital, Trabzon, Türkiye.
  • Department of Cardiology, University of Health Sciences Trabzon Kanuni Training and Research Hospital, Trabzon, Türkiye. Electronic address: fgulcelebi10@gmail.com.
  • Department of Cardiology, University of Health Sciences Trabzon Kanuni Training and Research Hospital, Trabzon, Türkiye.
  • Department of Physiotherapy and Rehabilitation, Tarsus University Faculty of Health Sciences, Mersin, Türkiye.
  • Department of Cardiology, University of Health Sciences Trabzon Ahi Evren Thoracic and Cardiovascular Surgery Training and Research Hospital, Trabzon, Türkiye.

Zitieren

APA

Altıntepe, S., Gülçebi, F., Özderya, A., Bellur, N., & Kalaycıoğlu, E. (2026). Comparison of device-based and bioelectrical impedance methods for volume status assessment in heart failure patients with cardiac implantable electronic devices (CIED vs. BIA fluid assessment in heart failure). Indian Pacing and Electrophysiology Journal, 26(5), 516-522. https://doi.org/10.1016/j.ipej.2026.08.001

Vancouver

Altıntepe S, Gülçebi F, Özderya A, Bellur N, Kalaycıoğlu E. Comparison of device-based and bioelectrical impedance methods for volume status assessment in heart failure patients with cardiac implantable electronic devices (CIED vs. BIA fluid assessment in heart failure). Indian Pacing and Electrophysiology Journal. 2026;26(5):516-522. doi:10.1016/j.ipej.2026.08.001

BibTeX
@article{Altntepe2026,
  author = {Altıntepe, Sedat and Gülçebi, Fatih and Özderya, Ahmet and Bellur, Nurel and Kalaycıoğlu, Ezgi},
  title = {Comparison of device-based and bioelectrical impedance methods for volume status assessment in heart failure patients with cardiac implantable electronic devices (CIED vs. BIA fluid assessment in heart failure)},
  journal = {Indian Pacing and Electrophysiology Journal},
  year = {2026},
  volume = {26},
  number = {5},
  pages = {516--522},
  doi = {10.1016/j.ipej.2026.08.001}
}
Kostenlos starten →