Assessing quantitative performance and expert review of multiple deep learning-based frameworks for computed tomography-based abdominal organ auto-segmentation
Intelligent Oncology · 2025
DOI: 10.1016/j.intonc.2025.03.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Intelligent Oncology, 2025. Verfasst von Udbhav S Ram und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, 35233, United States. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, NCI NIH HHS, Indiana University.
Abstract (Originalsprache)
Background
Segmentation of abdominal organs in computed tomography (CT) images within clinical oncological workflows is crucial for ensuring effective treatment planning and follow-up. However, manually generated segmentations are time-consuming and labor-intensive in addition to being subject to inter-observer variability. Many deep learning (DL) and Automated Machine Learning (AutoML) frameworks have emerged as a solution to this challenge and show promise in clinical workflows.
Objective
This study presents a comprehensive evaluation of existing AutoML frameworks (Auto3DSeg, nnU-Net) against a state-of-the-art non-AutoML framework, the Shifted Window U-Net Transformer (SwinUNETR).
Methods
Each framework was trained on the same 122 training images, taken from the Abdominal Multi-Organ Segmentation (AMOS) grand challenge. Frameworks were compared using Dice Similarity Coefficient (DSC), Surface DSC (sDSC), and 95th Percentile Hausdorff Distances (HD95) on an additional 72 holdout-validation images. The perceived clinical viability of 30 auto-contoured test cases was assessed by three physicians in a blinded evaluation.
Results
Comparisons show significantly better performance by AutoML methods. nnU-Net (average DSC: 0.924, average sDSC: 0.938, average HD95: 4.26, median Likert: 4.57), Auto3DSeg (average DSC: 0.902, average sDSC: 0.919, average HD95: 8.76, median Likert: 4.49), and SwinUNETR (average DSC: 0.837, average sDSC: 0.844, average HD95: 13.93). AutoML frameworks were quantitatively preferred (13/13 OARs P >0.0.5 in DSC and sDSC, 12/13 OARs P>0.05 in HD95, comparing Auto3DSeg to SwinUNETR, and all OARs P>0.05 in all metrics comparing SwinUNETR to nnU-Net). Qualitatively, nnU-Net was preferred over Auto3DSeg (P=0.0027).
Conclusion
The findings suggest that AutoML frameworks offer a significant advantage in the segmentation of abdominal organs, and underscores the potential of AutoML methods to enhance the efficiency of oncological workflows.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, 35233, United States.
Förderung
- NCATS NIH HHS
- NCI NIH HHS
- Indiana University
- National Cancer Institute
- National Center for Advancing Translational Sciences
- University of Alabama
- National Institutes of Health
- National Science Foundation
Zitieren
APA
Ram, U. S., Pogue, J. A., Soike, M., Pfister, N. T., Jacob, R., & Cardenas, C. E. (2025). Assessing quantitative performance and expert review of multiple deep learning-based frameworks for computed tomography-based abdominal organ auto-segmentation. Intelligent Oncology. https://doi.org/10.1016/j.intonc.2025.03.003
Vancouver
Ram US, Pogue JA, Soike M, Pfister NT, Jacob R, Cardenas CE. Assessing quantitative performance and expert review of multiple deep learning-based frameworks for computed tomography-based abdominal organ auto-segmentation. Intelligent Oncology. 2025. doi:10.1016/j.intonc.2025.03.003
BibTeX
@article{Ram2025,
author = {Ram, Udbhav S and Pogue, Joel A and Soike, Michael and Pfister, Neil T and Jacob, Rojymon and Cardenas, Carlos E},
title = {Assessing quantitative performance and expert review of multiple deep learning-based frameworks for computed tomography-based abdominal organ auto-segmentation},
journal = {Intelligent Oncology},
year = {2025},
doi = {10.1016/j.intonc.2025.03.003}
}
EUVIMED