EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters

Jiayu Li, Haoran Zhao, Marion L. Russell, William W. Delp, Alexandra Johnson, Xiaochen Tang, Iain S. Walker, Brett C. Singer

Indoor Environments · 2024-12 · 1 (4) · 100047

DOI: 10.1016/j.indenv.2024.100047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indoor Environments, 2024-12. Verfasst von Jiayu Li und 7 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: United States Environmental Protection Agency, U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compares air pollutant concentrations resulting from cooking with gas or induction cooktops, with or without either of two recirculating range hoods with filters. A meal of pasta, plant-based “meat” sauce and stir-fried broccoli was cooked three times for each cooktop and hood combination in a 158 m3 room. Time-resolved measurements were made of nitrogen oxides (NOX), carbon dioxide (CO2), size-resolved particles, and speciated volatile organic compounds (VOCs) during cooking and 30 minutes after cooking. Cooking with induction used half as much energy, produced no discernible NOX, and significantly reduced ultrafine particles (UFP, diameter < 100 nm) and CO2 compared to gas cooktops. Induction produced statistically higher PM2.5 when calculated using size-resolved particle measurements from one pair of instruments, but the difference was not discernible when calculating from another pair. With gas cooktops, roughly half of the PM2.5 was in particles smaller than 0.3 μm and thus below the lower quantitation threshold for many optical particle instruments; optical devices may thus substantially under-report PM2.5 from gas cooking. VOCs did not significantly differ between gas and induction. Both recirculating range hoods substantially reduced all particle sizes when cooking with either fuel, and the reductions were larger for gas cooking. One of the range hoods also substantially lowered some of the VOCs.

Förderung

  • United States Environmental Protection Agency
  • U.S. Department of Energy
  • Office of Energy Efficiency and Renewable Energy

Zitieren

APA

Li, J., Zhao, H., Russell, M. L., Delp, W. W., Johnson, A., Tang, X., Walker, I. S., & Singer, B. C. (2024). Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters. Indoor Environments, 1(4), 100047. https://doi.org/10.1016/j.indenv.2024.100047

Vancouver

Li J, Zhao H, Russell ML, Delp WW, Johnson A, Tang X, et al. Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters. Indoor Environments. 2024;1(4):100047. doi:10.1016/j.indenv.2024.100047

BibTeX
@article{Li2024,
  author = {Li, Jiayu and Zhao, Haoran and Russell, Marion L. and Delp, William W. and Johnson, Alexandra and Tang, Xiaochen and Walker, Iain S. and Singer, Brett C.},
  title = {Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters},
  journal = {Indoor Environments},
  year = {2024},
  volume = {1},
  number = {4},
  pages = {100047},
  doi = {10.1016/j.indenv.2024.100047}
}
Kostenlos starten →