EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Impulse oscillometry: An adjunct or alternative to spirometry in the diagnosis of obstructive airway disease. Results from an observational study

Rishabh Maheshwari, Anubhuti Singh, Pramod Shriram Chaudhari, Medha Deepak Bargaje, Kislay Kishore

Indian Journal of Tuberculosis · 2026

DOI: 10.1016/j.ijtb.2025.01.007 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Indian Journal of Tuberculosis, 2026. Verfasst von Rishabh Maheshwari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory Medicine, Bharati Vidyapeeth Deemed to be University, Pune, Maharashtra, India. Electronic address: rishabh.maheshwari01@gm…. Hauptthemen laut MEDLINE: Oscillometry, Pulmonary Disease, Chronic Obstructive, Asthma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Obstructive airway disease is one of the leading causes of morbidity and mortality in India. Spirometry is the gold standard for diagnosis of OAD, but is difficult to perform and requires patient cooperation. Impulse oscillometry has been shown to be more sensitive in diagnosis of OAD in studies conducted outside India. MATERIALS AND METHODS: This was a cross sectional, observational study including 125 (63 asthma and 62 COPD) patients conducted at a tertiary care centre. All patients underwent spirometry and impulse oscillometry and parameters were compared. RESULTS: Patients with asthma were significantly younger (p < 0.001), predominantly female (p < 0.001), had a history of allergy (p < 0.001) and a family history of OAD (p < 0.001). COPD patients were significantly older, male, smokers (p < 0.001) and had a history of COVID-19 disease (p < 0.001). Upon comparing lung function, COPD patients in our study had significantly lower post FEV1/FVC% (p = 0.001) and PEFR (p = 0.006) and significantly higher R5 (p = 0.008), R5-R20 (p = 0.046) and AX (p = 0.014) in comparison to asthma patients. We found that increased small airway resistance (SAD) is associated with reduced lung function in both the groups. We found expiratory flow limitation (EFL) in 72.6% COPD patients. Using 40% decrease in X5 as a criterion, we identified a significantly higher number of patients with bronchodilator responsiveness (P < 0.001). CONCLUSION: R5, R5-R20 and AX can be used to differentiate between asthma and COPD. SAD is associated with reduced lung function in both group of patients. IOS parameters are more sensitive in diagnosis of bronchodilator responsiveness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OscillometryPulmonary Disease, Chronic ObstructiveAsthmaHumansMaleSpirometryCross-Sectional StudiesFemaleMiddle AgedIndiaAdultBronchodilator Agents

Stichwörter der Autor:innen

Bronchial asthmaBronchodilator responseChronic obstructive pulmonary diseaseImpulse oscillometryObstructive airway diseaseSpirometry

Substanzen

Bronchodilator Agents

Autor:innen und Institutionen

  • Department of Respiratory Medicine, Bharati Vidyapeeth Deemed to be University, Pune, Maharashtra, India. Electronic address: rishabh.maheshwari01@gmail.com.
  • Department of Respiratory Medicine, Bharati Vidyapeeth Deemed to be University, Pune, Maharashtra, India. Electronic address: anubhutikgmu27@gmail.com.
  • Department of Respiratory Medicine, Bharati Vidyapeeth Deemed to be University, Pune, Maharashtra, India. Electronic address: pramoddto@gmail.com.
  • Department of Respiratory Medicine, Bharati Vidyapeeth Deemed to be University, Pune, Maharashtra, India. Electronic address: medhabargaje@yahoo.co.in.
  • Department of Respiratory Medicine, Army Institute of Cardiothoracic Sciences, Pune, Maharashtra, India. Electronic address: drkislay@gmail.com.

Zitieren

APA

Maheshwari, R., Singh, A., Chaudhari, P. S., Bargaje, M. D., & Kishore, K. (2026). Impulse oscillometry: An adjunct or alternative to spirometry in the diagnosis of obstructive airway disease. Results from an observational study. Indian Journal of Tuberculosis. https://doi.org/10.1016/j.ijtb.2025.01.007

Vancouver

Maheshwari R, Singh A, Chaudhari PS, Bargaje MD, Kishore K. Impulse oscillometry: An adjunct or alternative to spirometry in the diagnosis of obstructive airway disease. Results from an observational study. Indian Journal of Tuberculosis. 2026. doi:10.1016/j.ijtb.2025.01.007

BibTeX
@article{Maheshwari2026,
  author = {Maheshwari, Rishabh and Singh, Anubhuti and Chaudhari, Pramod Shriram and Bargaje, Medha Deepak and Kishore, Kislay},
  title = {Impulse oscillometry: An adjunct or alternative to spirometry in the diagnosis of obstructive airway disease. Results from an observational study},
  journal = {Indian Journal of Tuberculosis},
  year = {2026},
  doi = {10.1016/j.ijtb.2025.01.007}
}
Kostenlos starten →