Toward Optimal Fractionation Schemes in Nonuniform Radiation Therapy: Exploiting Helical Tomotherapy’s Thread Effect for Gynecological Cancer Treatment
International Journal of Radiation Oncology*Biology*Physics · 2026-10 · 126 (2) · 557-567
DOI: 10.1016/j.ijrobp.2026.03.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2026-10. Verfasst von Huanli Luo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, Chongqing University Cancer Hospital, Chongqing, China. Hauptthemen laut MEDLINE: Dose Fractionation, Radiation, Genital Neoplasms, Female, Radiotherapy, Intensity-Modulated, Uterine Cervical Neoplasms. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Chongqing Municipal Health Commission, Chongqing Science and Technology Commission.
Abstract (Originalsprache)
PURPOSE: This study aimed to optimize dose fractionation for helical tomotherapy-based spatially fractionated radiation therapy (HT-SFRT) in gynecologic cancers by exploiting the "thread effect" to induce cohort effects. METHODS AND MATERIALS: HT-SFRT plans with varying parameters (pitch: 0.3-0.5; field width: 2.512 and 5.048 cm; modulation factor: 1.0-4.0) were applied to HeLa cells to identify the optimal configuration maximizing the peak-to-valley dose ratio. The cohort effect threshold was determined through quantification of DNA damage (γ-H2AX) and cell viability. Clinical validation involved 45 patients with gynecologic cancer, comparing 3 treatment approaches: conventional HT, stereotactic body radiation therapy, and SFRT (3 and 4 fractions). Comprehensive dosimetric analysis included evaluation of physical doses, biologically effective doses, tumor control probability, and normal tissue complication probability (NTCP) using the universal survival curve and Lyman-Kutcher-Burman models. RESULTS: Optimized HT-SFRT parameters (field width = 5.048 cm; pitch = 0.5; modulation factor = 2.0) achieved a peak-to-valley dose ratio of 1.15 at 10 cm off-axis. The 8 Gy/fraction dose threshold induced significant γ-H2AX expression and reduced cell viability by 15.41% (P < .05), establishing the cohort effect criterion. Clinically, the 32 Gy/4 fractions SFRT regimen demonstrated approximate tumor control (tumor control probability: 99.34% vs 100%) to conventional HT (50 Gy/25 fractions), whereas offering superior therapeutic advantages: (1) 84% reduction in treatment duration (4 vs 25 days); (2) significantly lower NTCP for bladder (6.5 × 10-⁶ % vs 3.6 × 10-⁴ %, P = .05); and (3) 42.9% faster fractional delivery than stereotactic body radiation therapy. Notably, SFRT exhibited elevated NTCP for rectum (3.99% vs 0.10%) and femoral head (0.16%-0.22% vs 2.9 × 10-⁷ %-4.8 × 10-⁷ %) structures. CONCLUSIONS: The thread effect in HT can be harnessed for SFRT, avoiding traditional mitigation strategies. The optimized HT-SFRT scheme (32 Gy/4 fractions) offers equivalent tumor control, shorter treatment duration, and acceptable normal tissue toxicity, providing a promising alternative for gynecologic cancer radiation therapy. Prospective clinical trials are warranted to validate these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiation Physics, Chongqing University Cancer Hospital, Chongqing, China.
- Department of Radiation Oncology, Chongqing University Cancer Hospital, School of Medicine, Chongqing University, Chongqing, China.
- Yilong General Hospital, Nanchong, China.
- Department of Radiation Physics, Chongqing University Cancer Hospital, Chongqing, China. Electronic address: wangying1967_cq@126.com.
- Department of Radiation Physics, Chongqing University Cancer Hospital, Chongqing, China. Electronic address: jfazj@126.com.
Förderung
- National Natural Science Foundation of China
- Chongqing Municipal Health Commission
- Chongqing Science and Technology Commission
Zitieren
APA
Luo, H., Yang, M., Li, J., Qiu, T., Hu, W., Song, Y., Wang, T., Peng, H., Yang, X., Feng, B., Chen, L., Tan, L., Liang, B., Wang, Y., & Jin, F. (2026). Toward Optimal Fractionation Schemes in Nonuniform Radiation Therapy: Exploiting Helical Tomotherapy’s Thread Effect for Gynecological Cancer Treatment. International Journal of Radiation Oncology*Biology*Physics, 126(2), 557-567. https://doi.org/10.1016/j.ijrobp.2026.03.026
Vancouver
Luo H, Yang M, Li J, Qiu T, Hu W, Song Y, et al. Toward Optimal Fractionation Schemes in Nonuniform Radiation Therapy: Exploiting Helical Tomotherapy’s Thread Effect for Gynecological Cancer Treatment. International Journal of Radiation Oncology*Biology*Physics. 2026;126(2):557-567. doi:10.1016/j.ijrobp.2026.03.026
BibTeX
@article{Luo2026,
author = {Luo, Huanli and Yang, Mengqi and Li, Jianfeng and Qiu, Tao and Hu, Wenyou and Song, Yunrui and Wang, Tian and Peng, Haiyan and Yang, Xin and Feng, Bin and Chen, Liyuan and Tan, Liang and Liang, Bo and Wang, Ying and Jin, Fu},
title = {Toward Optimal Fractionation Schemes in Nonuniform Radiation Therapy: Exploiting Helical Tomotherapy’s Thread Effect for Gynecological Cancer Treatment},
journal = {International Journal of Radiation Oncology*Biology*Physics},
year = {2026},
volume = {126},
number = {2},
pages = {557--567},
doi = {10.1016/j.ijrobp.2026.03.026}
}