EUVIMEDEUVIMED entdecken
Crossref

Average Dose Rate is the Major Temporal Beam Structure Parameter for Preserving Murine Intestines With Pulsed Electron FLASH Radiation Therapy

Veljko Grilj, Anet Valdes Zayas, Anouk Sesink, Preethi Devanand, David Repáraz, Ryan Paisley, Kevin Sprengers, Katiuska Passelli, Julie Pernot, Till Tobais Böhlen, Reiner Walter Geyer, Raphael Moeckli und 6 weitere

International Journal of Radiation Oncology*Biology*Physics · 2025-10 · 123 (2) · 593-601

DOI: 10.1016/j.ijrobp.2025.04.021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2025-10. Verfasst von Veljko Grilj und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncology, Radiation Oncology Service, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Electronic addres…. Hauptthemen laut MEDLINE: Jejunum, Electrons, Organ Sparing Treatments, Radiation Injuries, Experimental. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Fondation ISREC, Biltema Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The relationship between the physical parameters of pulsed beams and the FLASH effect remains largely unexplored. Our research aimed to investigate systematically the beam requirements necessary for pulsed electron FLASH radiation therapy, which is characterized by high average dose rates (DRav) and large doses-per-pulse (DPP). METHODS AND MATERIALS: The abdominal cavity of tumor-free C57BL/6 mice was irradiated with a pulsed electron beam at 17 Gy, generated by a prototype electron linear accelerator. The time structure of the applied beams was varied by adjusting the pulse repetition frequency and the DPP. The overall survival was assessed for each group irradiated with different configurations of beam parameters. For some groups, jejunum samples were harvested at 96 hours postirradiation and the number of regenerating crypts per unit length was evaluated. RESULTS: Decreasing both DPP and DRav led to an increase in side effects and reduced overall survival. The observed toxicity was reduced by increasing DRav while maintaining a constant DPP, achieving a maximum FLASH sparing effect at a minimum DRav of 100 Gy/s. Conversely, lowering the DRav while maintaining a high DPP (>1 Gy/pulse) increased side effects with the subsequent reduction in overall survival. CONCLUSIONS: This research provides evidence that the DRav is the major temporal beam parameter for reproducing the FLASH normal tissue-sparing effect even in the case of pulsed radiation beams. A minimum dose rate of 100 Gy/s is necessary to maximize the sparing effect for intestines irradiated with 17 Gy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

JejunumElectronsOrgan Sparing TreatmentsRadiation Injuries, ExperimentalAnimalsMiceMice, Inbred C57BLRadiotherapy DosageTime FactorsParticle AcceleratorsRegeneration

Autor:innen und Institutionen

  • Department of Oncology, Radiation Oncology Service, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Electronic address: Veljko.Grilj@chuv.ch.
  • Department of Oncology, Radiation Oncology Service, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Institute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.
  • Institute of Pathology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Department of Oncology, Radiation Oncology Service, Service of Immuno Oncology, Ludwig Institute for Cancer Research, Agora Cancer Research Institute, Lausanne University Hospital and University of Lausanne, Lausanne, S…

Förderung

  • Fondation ISREC
  • Biltema Foundation

Zitieren

APA

Grilj, V., Zayas, A. V., Sesink, A., Devanand, P., Repáraz, D., Paisley, R., Sprengers, K., Passelli, K., Pernot, J., Böhlen, T. T., Geyer, R. W., Moeckli, R., Bailat, C., Germond, J. F., Dagher, J., Bochud, F., Bourhis, J., & Herrera, F. G. (2025). Average Dose Rate is the Major Temporal Beam Structure Parameter for Preserving Murine Intestines With Pulsed Electron FLASH Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics, 123(2), 593-601. https://doi.org/10.1016/j.ijrobp.2025.04.021

Vancouver

Grilj V, Zayas AV, Sesink A, Devanand P, Repáraz D, Paisley R, et al. Average Dose Rate is the Major Temporal Beam Structure Parameter for Preserving Murine Intestines With Pulsed Electron FLASH Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics. 2025;123(2):593-601. doi:10.1016/j.ijrobp.2025.04.021

BibTeX
@article{Grilj2025,
  author = {Grilj, Veljko and Zayas, Anet Valdes and Sesink, Anouk and Devanand, Preethi and Repáraz, David and Paisley, Ryan and Sprengers, Kevin and Passelli, Katiuska and Pernot, Julie and Böhlen, Till Tobais and Geyer, Reiner Walter and Moeckli, Raphael and Bailat, Claude and Germond, Jean-Francois and Dagher, Julien and Bochud, Francois and Bourhis, Jean and Herrera, Fernanda G},
  title = {Average Dose Rate is the Major Temporal Beam Structure Parameter for Preserving Murine Intestines With Pulsed Electron FLASH Radiation Therapy},
  journal = {International Journal of Radiation Oncology*Biology*Physics},
  year = {2025},
  volume = {123},
  number = {2},
  pages = {593--601},
  doi = {10.1016/j.ijrobp.2025.04.021}
}