EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Three-dimensional assessment of the malar bone implant engagement of 100 zygomatic implants: a retrospective study

F Zingari, F Gallo, A Madonna, S Barone, M Borelli, A Giudice

International Journal of Oral and Maxillofacial Surgery · 2026

DOI: 10.1016/j.ijom.2025.08.009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Oral and Maxillofacial Surgery, 2026. Verfasst von F Zingari und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy. Hauptthemen laut MEDLINE: Zygoma, Imaging, Three-Dimensional, Dental Implants, Dental Implantation, Endosseous. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study was performed to evaluate the amount of bone implant engagement (BIE) of zygomatic implants (ZIs) at the malar bone level and its correlation with the ZAGA classification (zygoma anatomy-guided approach). One hundred ZIs placed in 32 patients with severe maxillary atrophy using a fully digital protocol were assessed: 80 placed in pairs (40 anterior (AI), 40 posterior (PI)) and 20 as single ZIs (SI). The ZAGA classification was determined preoperatively. Postoperative computed tomography scans were analysed using 3D Slicer to measure medial and lateral BIE, the mean value of these (mvBIE), and the ferrule area. Comparisons of the mean mvBIE of the implants (AI, PI, SI) were made according to the ZAGA categories and within each ZAGA group. Descriptive statistics and a linear mixed-effects model were performed (α = 0.05). The overall mean mvBIE was 12.38 ± 3.53 mm (AI: 12.38 ± 3.85 mm, PI: 11.50 ± 3.01 mm, SI: 14.16 ± 3.32 mm). A significant relationship was found between mvBIE and the ZAGA classification (0.005

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ZygomaImaging, Three-DimensionalDental ImplantsDental Implantation, EndosseousMaxillaHumansRetrospective StudiesFemaleMaleMiddle AgedAdultTomography, X-Ray ComputedAgedTreatment Outcome

Stichwörter der Autor:innen

Bone-implant interfaceEndosseous dental implantationGuided surgeryThree-dimensional imagingZygoma

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Ospedale Galeazzi-Sant'Ambrogio, Milan, Italy.
  • Istituto Stomatologico Italiano, Milan, Italy.
  • School of Dentistry, Department of Health Science, Magna Graecia University of Catanzaro, Catanzaro, Italy.
  • School of Dentistry, Department of Health Science, Magna Graecia University of Catanzaro, Catanzaro, Italy. Electronic address: selene.barone@unicz.it.
  • School of PhD Programmes Life Science and Technologies, Magna Graecia University of Catanzaro, Catanzaro, Italy.

Zitieren

APA

Zingari, F., Gallo, F., Madonna, A., Barone, S., Borelli, M., & Giudice, A. (2026). Three-dimensional assessment of the malar bone implant engagement of 100 zygomatic implants: a retrospective study. International Journal of Oral and Maxillofacial Surgery. https://doi.org/10.1016/j.ijom.2025.08.009

Vancouver

Zingari F, Gallo F, Madonna A, Barone S, Borelli M, Giudice A. Three-dimensional assessment of the malar bone implant engagement of 100 zygomatic implants: a retrospective study. International Journal of Oral and Maxillofacial Surgery. 2026. doi:10.1016/j.ijom.2025.08.009

BibTeX
@article{Zingari2026,
  author = {Zingari, F and Gallo, F and Madonna, A and Barone, S and Borelli, M and Giudice, A},
  title = {Three-dimensional assessment of the malar bone implant engagement of 100 zygomatic implants: a retrospective study},
  journal = {International Journal of Oral and Maxillofacial Surgery},
  year = {2026},
  doi = {10.1016/j.ijom.2025.08.009}
}
Kostenlos starten →