Multimodal image-guided surgical robot versus 3D-printed template for brachytherapy of malignant tumours in the skull base and deep facial region: a clinical comparative study
International Journal of Oral and Maxillofacial Surgery · 2025
DOI: 10.1016/j.ijom.2024.09.002 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Oral and Maxillofacial Surgery, 2025. Verfasst von N Jin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical School of Chinese PLA, Beijing, China; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China. Hauptthemen laut MEDLINE: Brachytherapy, Printing, Three-Dimensional, Robotic Surgical Procedures, Skull Base Neoplasms. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
This study compared a multimodal image-guided robot and three-dimensionally (3D) printed templates for implanting iodine-125 (I125) radioactive seeds in patients with malignant tumours in the skull base and deep facial region. Seventeen patients who underwent I125 radioactive seed implantation between December 2018 and December 2019 were included. The operation time, intraoperative blood loss, and accuracy of seed implantation were compared between the multimodal image-guided robot-assisted implantation (experimental) group (n = 7) and 3D-printed template-assisted implantation (control) group (n = 10). In total, 291 seeds were implanted in the experimental group and 436 in the control group; the mean error of seed implantation accuracy was 1.95 ± 0.13 mm and 1.90 ± 0.08 mm, respectively (P = 0.309). The preparation time was 26.13 ± 5.28 min in the experimental group and 0 min in the control group, while the average operation time was 34.44 ± 6.39 min versus 43.70 ± 6.06 min, respectively. The intraoperative blood loss was 4.96 ± 1.76 ml (experimental) versus 8.97 ± 2.99 ml (control) (P = 0.123). Multimodal image-guided robot-assisted I125 radioactive seed implantation met the clinical requirements for treating malignant tumours in the skull base and deep facial regions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical School of Chinese PLA, Beijing, China; Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
- Medical School of Chinese PLA, Beijing, China; Department of Stomatology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
- Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
- Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China. Electronic address: zhanghaizhong@301hospital.com.cn.
Zitieren
APA
Jin, N., Meng, F., Zhu, L., Xing, L., Lin, Q., & Zhang, H. (2025). Multimodal image-guided surgical robot versus 3D-printed template for brachytherapy of malignant tumours in the skull base and deep facial region: a clinical comparative study. International Journal of Oral and Maxillofacial Surgery. https://doi.org/10.1016/j.ijom.2024.09.002
Vancouver
Jin N, Meng F, Zhu L, Xing L, Lin Q, Zhang H. Multimodal image-guided surgical robot versus 3D-printed template for brachytherapy of malignant tumours in the skull base and deep facial region: a clinical comparative study. International Journal of Oral and Maxillofacial Surgery. 2025. doi:10.1016/j.ijom.2024.09.002
BibTeX
@article{Jin2025,
author = {Jin, N and Meng, F and Zhu, L and Xing, L and Lin, Q and Zhang, H},
title = {Multimodal image-guided surgical robot versus 3D-printed template for brachytherapy of malignant tumours in the skull base and deep facial region: a clinical comparative study},
journal = {International Journal of Oral and Maxillofacial Surgery},
year = {2025},
doi = {10.1016/j.ijom.2024.09.002}
}