Continuous epidural infusion versus programmed-intermittent epidural bolus for labor analgesia and vacuum-assisted vaginal delivery rates: a retrospective cohort study (2020–2021)
International Journal of Obstetric Anesthesia · 2025
DOI: 10.1016/j.ijoa.2025.104378 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Obstetric Anesthesia, 2025. Verfasst von D Karol und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Affiliated to the Faculty of Medicine and Health Scie…. Hauptthemen laut MEDLINE: Vacuum Extraction, Obstetrical, Analgesia, Epidural, Analgesia, Obstetrical, Analgesia, Patient-Controlled. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Studies suggest that programmed intermittent epidural bolus (PIEB) with patient-controlled epidural analgesia (PCEA) for labor epidural analgesia maintenance provides better analgesia, greater maternal mobility during labor, and improved obstetric outcomes compared with continuous epidural infusion (CEI) with PCEA. However instrumental vaginal delivery rates with PIEB/PCEA remain underreported. METHODS: Following implementation of PIEB/PCEA in our institution, a retrospective study was conducted comparing outcomes with CEI/PCEA (July to December 2020) vs. PIEB/PCEA (July to December 2021). The primary outcome was the vacuum-assisted vaginal delivery rate. Secondary outcomes were the number of physician-administered epidural boluses, the rate of episiotomies and vaginal lacerations, rate of conversion to cesarean delivery and the rate of successful conversion to epidural surgical anesthesia in the latter. There were no exclusion criteria. RESULTS: There were 7610 cases with labor epidural analgesia, CEI/PCEA 3934 (51.7%) and PIEB/PCEA 3676 (48.3%). There was no difference in the rate of vacuum-assisted delivery with PIEB/PCEA (14.1%) or CEI/PCEA (13.3%) (OR 1.07, 95% CI 0.94-1.22, P =0.34). With PIEB/PCEA, women were less likely to receive physician-administered epidural boluses. CONCLUSIONS: PIEB/PCEA was associated with comparable rates of vacuum-assisted delivery as CEI/PCEA, with lower rates of physician-administered epidural boluses, suggesting better quality of labor epidural analgesia with PIEB/PCEA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Affiliated to the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel. Electronic address: danak…
- Division of Anesthesia, Intensive Care, and Pain, Tel-Aviv Medical Center, Tel-Aviv University, Affiliated to the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
- Department of Obstetrics and Gynecology, Lis Maternity Hospital, Tel Aviv Medical Center, Affiliated to the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
Zitieren
APA
Karol, D., Zarour, S., Aptekman, B., Lavie, A., Weiniger, C. F., & Rabkin, V. (2025). Continuous epidural infusion versus programmed-intermittent epidural bolus for labor analgesia and vacuum-assisted vaginal delivery rates: a retrospective cohort study (2020–2021). International Journal of Obstetric Anesthesia. https://doi.org/10.1016/j.ijoa.2025.104378
Vancouver
Karol D, Zarour S, Aptekman B, Lavie A, Weiniger CF, Rabkin V. Continuous epidural infusion versus programmed-intermittent epidural bolus for labor analgesia and vacuum-assisted vaginal delivery rates: a retrospective cohort study (2020–2021). International Journal of Obstetric Anesthesia. 2025. doi:10.1016/j.ijoa.2025.104378
BibTeX
@article{Karol2025,
author = {Karol, D and Zarour, S and Aptekman, B and Lavie, A and Weiniger, C F and Rabkin, V},
title = {Continuous epidural infusion versus programmed-intermittent epidural bolus for labor analgesia and vacuum-assisted vaginal delivery rates: a retrospective cohort study (2020–2021)},
journal = {International Journal of Obstetric Anesthesia},
year = {2025},
doi = {10.1016/j.ijoa.2025.104378}
}
EUVIMED