EUVIMEDEUVIMED entdecken
VergleichsstudieÄquivalenzstudieRandomisierte kontrollierte Studie

Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial

M Gupta, D Jain, K Jain, K Gandhi, A Arora

International Journal of Obstetric Anesthesia · 2024-08 · 59 · 103997

DOI: 10.1016/j.ijoa.2024.103997 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Journal of Obstetric Anesthesia, 2024-08. Verfasst von M Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Hauptthemen laut MEDLINE: Cesarean Section, Cricoid Cartilage, Pressure. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Cricoid pressure has been surrounded with controversies regarding its effectiveness. Application of ultrasound-guided para-laryngeal (PL) force has been shown to occlude the esophagus effectively compared with cricoid pressure (CP) in awake patients. We hypothesized that there would be no meaningful difference in the change in antero-posterior esophageal diameter from with application of cricoid or para-laryngeal pressure in parturients undergoing cesarean delivery under general anesthesia. METHODS: In this prospective, randomized, non-inferiority trial, 40 parturients scheduled for elective cesarean delivery under general anesthesia were randomized to receive rapid sequence induction with either cricoid pressure (n = 20) or para-laryngeal pressure (n = 20). The antero-posterior diameter of the esophagus, measured by sonography, was the primary outcome. Visualization of the esophagus, its position in relation to the glottic aperture, esophageal occlusion, percentage of glottic opening (POGO), time to intubation, first pass success rate, overall success rate and adverse events like desaturation or bronchospasm were secondary outcomes. RESULTS: The mean change in anterior-posterior diameter in the CP group was 0.17 ±0.1 cm vs. 0.28 ±0.1 cm in the PL group. The mean difference (CP-para-laryngeal pressure) between the groups was -0.11 (95% CI -0.17 to -0.1) cm. As the upper limit of the 95% CI was lower than the prespecified non-inferiority margin (δ = -0.2), non-inferiority was established (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cesarean SectionCricoid CartilagePressureAdultFemaleHumansPregnancyAnesthesia, GeneralAnesthesia, ObstetricalIntubation, IntratrachealLarynxProspective Studies

Stichwörter der Autor:innen

Airway managementAnesthesia, generalAnesthesia, obstetricCricoid pressure

Autor:innen und Institutionen

  • Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Electronic address: jaindivya77@rediffmail.com.
  • Department of Obstetrics and Gynaecology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.

Zitieren

APA

Gupta, M., Jain, D., Jain, K., Gandhi, K., & Arora, A. (2024). Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial. International Journal of Obstetric Anesthesia, 59, 103997. https://doi.org/10.1016/j.ijoa.2024.103997

Vancouver

Gupta M, Jain D, Jain K, Gandhi K, Arora A. Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial. International Journal of Obstetric Anesthesia. 2024;59:103997. doi:10.1016/j.ijoa.2024.103997

BibTeX
@article{Gupta2024,
  author = {Gupta, M and Jain, D and Jain, K and Gandhi, K and Arora, A},
  title = {Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial},
  journal = {International Journal of Obstetric Anesthesia},
  year = {2024},
  volume = {59},
  pages = {103997},
  doi = {10.1016/j.ijoa.2024.103997}
}
Kostenlos starten →