EUVIMEDEUVIMED entdecken
VergleichsstudieStudienprotokoll

Comparison of rapid antimicrobial susceptibility testing of flash positive blood culture bottles using disk diffusion and automated broth microdilution on VITEK 2 compact with standard methods: Clinical Laboratory Standards Institute (CLSI) protocol

Prerna S Salian, Dhruti Sheth, Anurag K Bari, Aruna Poojary, Seema Rohra, Minipriyaa R

Indian Journal of Medical Microbiology · 2025

DOI: 10.1016/j.ijmmb.2025.100809 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Indian Journal of Medical Microbiology, 2025. Verfasst von Prerna S Salian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India. Electronic address: prernassalian@gmail.com. Hauptthemen laut MEDLINE: Blood Culture, Anti-Bacterial Agents, Bacteria, Disk Diffusion Antimicrobial Tests. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Sepsis requires prompt diagnosis for effective management. Standard Antimicrobial Susceptibility Testing (AST) is time-consuming, highlighting the need for Rapid Antimicrobial Susceptibility Testing (RAST) to provide reports earlier. PURPOSE: To compare the results of RAST and AST in order to determine the feasibility and reliability of RAST. MATERIALS AND METHODS: A study at a tertiary care facility analyzed 95 positive blood culture isolates. RAST was performed by Disk Diffusion (DD) and VITEK 2 Compact Automated Broth Microdilution (BMD) from flagged positive broth. In contrast, AST was performed by DD and BMD from isolated colonies. RESULTS: Among 95 Gram-negative bacteria (GNB), E. coli (n = 40), and K. pneumoniae (n = 19) were most common. RAST vs AST DD for GNB showed 91 % Categorical agreement (CA) with an overall Very Major Error (VME) and Major Error (ME) rates of 0.7 % & 2.2 % and respectively. For GNB, RAST vs. AST BMD demonstrated a CA of 97 % and Essential Agreement (EA) of 97.7 %, with VME and ME rates of 1.7 % (excluding E.coli + Cefepime drug bug pairs) and 0.1 % respectively. CONCLUSION: These findings suggest that RAST is a reliable antimicrobial susceptibility tool for GNB from direct Blood Culture broths. RAST can support early initiation of targeted antimicrobial therapy in patients with sepsis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood CultureAnti-Bacterial AgentsBacteriaDisk Diffusion Antimicrobial TestsGram-Negative BacteriaHumansMicrobial Sensitivity TestsSepsisReproducibility of ResultsBacteremiaTertiary Care Centers

Stichwörter der Autor:innen

ASTBlood culturesBloodstream infectionsRASTSepsis

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India. Electronic address: prernassalian@gmail.com.
  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India; Department of Microbiology, Nanavati Max Super speciality Hospital , Mumbai, India. Electronic address: dsheth161088@gmail.com.
  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India; Department of Medical Microbiology and Infection Prevention, University Medical Centre, Groningen, Netherlands. Electronic add…
  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India. Electronic address: arunapoojary@gmail.com.
  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India. Electronic address: seema.kukreja@breachcandyhospital.org.
  • Department of Pathology and Microbiology, Breach Candy Hospital Trust (BCHT), Mumbai, India. Electronic address: drminipriyaa@gmail.com.

Zitieren

APA

Salian, P. S., Sheth, D., Bari, A. K., Poojary, A., Rohra, S., & R, M. (2025). Comparison of rapid antimicrobial susceptibility testing of flash positive blood culture bottles using disk diffusion and automated broth microdilution on VITEK 2 compact with standard methods: Clinical Laboratory Standards Institute (CLSI) protocol. Indian Journal of Medical Microbiology. https://doi.org/10.1016/j.ijmmb.2025.100809

Vancouver

Salian PS, Sheth D, Bari AK, Poojary A, Rohra S, R M. Comparison of rapid antimicrobial susceptibility testing of flash positive blood culture bottles using disk diffusion and automated broth microdilution on VITEK 2 compact with standard methods: Clinical Laboratory Standards Institute (CLSI) protocol. Indian Journal of Medical Microbiology. 2025. doi:10.1016/j.ijmmb.2025.100809

BibTeX
@article{Salian2025,
  author = {Salian, Prerna S and Sheth, Dhruti and Bari, Anurag K and Poojary, Aruna and Rohra, Seema and R, Minipriyaa},
  title = {Comparison of rapid antimicrobial susceptibility testing of flash positive blood culture bottles using disk diffusion and automated broth microdilution on VITEK 2 compact with standard methods: Clinical Laboratory Standards Institute (CLSI) protocol},
  journal = {Indian Journal of Medical Microbiology},
  year = {2025},
  doi = {10.1016/j.ijmmb.2025.100809}
}