Accuracy of various matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based rapid identification methods—As a tool to augment diagnostic stewardship in blood culture laboratory, South India
Indian Journal of Medical Microbiology · 2024
DOI: 10.1016/j.ijmmb.2024.100747 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Indian Journal of Medical Microbiology, 2024. Verfasst von Sonali Padhy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Dept. of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, 605006, India. Electronic address: doc.sonali…. Hauptthemen laut MEDLINE: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Blood Culture, Bacteria. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Jawaharlal Institute Of Postgraduate Medical Education and Research.
Abstract (Originalsprache)
BACKGROUND: Blood stream infection is a medical emergency associated with high morbidity and mortality. Prompt identification of bloodstream infection-causing microorganisms directly from positive blood culture will significantly enhance patient care by reducing the turnaround time of pathogen recognition. METHODS: A total of 256 freshly flagged positive blood culture bottles were subjected to Gram staining. Direct MALDI-TOF MS analysis was performed following sample preparation techniques such as lysis centrifugation, lysis filtration and VITEK® MS BC kit to directly identify microorganisms from positive blood cultures. Along with these short-term incubation methods of Choco spot and minute colony(8-10h) were also performed. All those positive bottles were identified by the routine (reference) laboratory method. RESULTS: 177 isolates (69.14 %) were correctly identified by Lysis centrifugation, 163 isolates (63.67 %) were correctly identified by Lysis filtration, 206 isolates (80.47 %) were correctly identified by Choco spot,250 isolates (97.65 %) were correctly identified from minute colony (8-10h) of incubation. Of 162 isolates,115 isolates (70.99 %) were correctly identified by VITEK® MS Blood culture kit, (BioMérieux). VITEK® MS BC kit method revealed higher agreement with the kappa value of 0.697 than lysis centrifugation (0.672) followed by lysis filtration (0.611). CONCLUSIONS: In house method of lysis centrifugation is found to be equivalent to VITEK® MS BC kit method and superior to lysis filtration method in correct direct identification of bacteria from positive blood cultures by MALDI-TOF MS analysis. As lysis centrifugation requires only 10 min of processing time as compared to overnight incubation, thus it offers a less expensive substitute for the VITEK® MS BC kit in the clinical laboratory. As a consequence of this study, we have implemented direct MALDI-TOF-based identification from positive BCs in our daily routine diagnostic management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dept. of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, 605006, India. Electronic address: doc.sonali28@gmail.com.
- Dept. of Microbiology, All India Institute of Medical Sciences, Patna, 801507, India. Electronic address: ketprirule@gmail.com.
- Dept. of Microbiology, Sri Devaraj Urs Medical College, Kolar, India, 563101, India. Electronic address: drsarumicro@gmail.com.
- Dept. of Microbiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, 605006, India. Electronic address: drapurbasastry@gmail.com.
Förderung
- Jawaharlal Institute Of Postgraduate Medical Education and Research
Zitieren
APA
Padhy, S., Priyadarshi, K., Dhandapani, S., & Sastry, A. S. (2024). Accuracy of various matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based rapid identification methods—As a tool to augment diagnostic stewardship in blood culture laboratory, South India. Indian Journal of Medical Microbiology. https://doi.org/10.1016/j.ijmmb.2024.100747
Vancouver
Padhy S, Priyadarshi K, Dhandapani S, Sastry AS. Accuracy of various matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based rapid identification methods—As a tool to augment diagnostic stewardship in blood culture laboratory, South India. Indian Journal of Medical Microbiology. 2024. doi:10.1016/j.ijmmb.2024.100747
BibTeX
@article{Padhy2024,
author = {Padhy, Sonali and Priyadarshi, Ketan and Dhandapani, Sarumathi and Sastry, Apurba Sankar},
title = {Accuracy of various matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based rapid identification methods—As a tool to augment diagnostic stewardship in blood culture laboratory, South India},
journal = {Indian Journal of Medical Microbiology},
year = {2024},
doi = {10.1016/j.ijmmb.2024.100747}
}
EUVIMED