Low-frequency vibration absorption of magnetic quasi-zero-stiffness structures with lever mechanism
International Journal of Mechanical Sciences · 2024-04 · 267 · 108973
DOI: 10.1016/j.ijmecsci.2024.108973 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Mechanical Sciences, 2024-04. Verfasst von Ning Yu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 75 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Mechanical System and Vibration.
Abstract (Originalsprache)
13 Dynamic vibration absorbers (DVAs) are widely employed in diverse engineering 14 systems for their capacity to mitigate structural vibrations. However, traditional 15 absorbers exhibit sensitivity to natural frequencies and present challenges in tuning 16 within the low-frequency range. This study introduces a lever mechanism to enhance 17 the low-frequency vibration absorption performance of magnetic quasi-zero-stiffness 18 structures, resulting in a lever-type DVA (L-DVA). We elucidate the design philosophy 19 behind the proposed L-DVA. An analytical model is derived based on the Lagrange 20 equation and the frequency-response relationship is determined using the harmonic 21 balance method. We conduct numerical and experimental analyses to assess the impact 22 of the lever ratio, mass ratio, frequency ratio, nonlinear stiffness coefficient ratio, and 23 damping ratio on vibration absorption performance. Furthermore, we fabricate a 24 prototype of the L-DVA with an adjustable magnetic quasi-zero-stiffness structure, and 25 the experimental results align with simulation outcomes. The result shows that this 26 study is the ease of customization in the vibration absorption capabilities of magnetic 27 quasi-zero-stiffness structures, achieved by adjusting the lever ratio. An increase in the 28
Förderung
- National Natural Science Foundation of China
- State Key Laboratory of Mechanical System and Vibration
Zitieren
APA
Yu, N., Yang, K., Wu, Z., Zhang, W., & Yan, B. (2024). Low-frequency vibration absorption of magnetic quasi-zero-stiffness structures with lever mechanism. International Journal of Mechanical Sciences, 267, 108973. https://doi.org/10.1016/j.ijmecsci.2024.108973
Vancouver
Yu N, Yang K, Wu Z, Zhang W, Yan B. Low-frequency vibration absorption of magnetic quasi-zero-stiffness structures with lever mechanism. International Journal of Mechanical Sciences. 2024;267:108973. doi:10.1016/j.ijmecsci.2024.108973
BibTeX
@article{Yu2024,
author = {Yu, Ning and Yang, Kai and Wu, Zhangming and Zhang, Wenming and Yan, Bo},
title = {Low-frequency vibration absorption of magnetic quasi-zero-stiffness structures with lever mechanism},
journal = {International Journal of Mechanical Sciences},
year = {2024},
volume = {267},
pages = {108973},
doi = {10.1016/j.ijmecsci.2024.108973}
}