The association between O2-pulse slope ratio and functional severity of coronary stenosis: A combined cardiopulmonary exercise testing and quantitative flow ratio study
IJC Heart & Vasculature · 2024-06 · 52 · 101409
DOI: 10.1016/j.ijcha.2024.101409 ↗Kurz gefasst
Fachartikel in der Zeitschrift IJC Heart & Vasculature, 2024-06. Verfasst von Liang Geng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, East Hospital, Tongji University, Shanghai 200120, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Shanghai City Pudong New Area People's Government.
Abstract (Originalsprache)
Background
The role of cardiopulmonary exercise testing (CPET) parameters in evaluating the functional severity of coronary disease remains unclear. The aim of this study was to quantify the O2-pulse morphology and investigate its relevance in predicting the functional severity of coronary stenosis, using Murray law-based quantitative flow ratio (μQFR) as the reference.
Methods
CPET and μQFR were analyzed in 138 patients with stable coronary artery disease (CAD). The O2-pulse morphology was quantified through calculating the O2-pulse slope ratio. The presence of O2-pulse plateau was defined according to the best cutoff value of O2-pulse slope ratio for predicting μQFR ≤ 0.8.
Results
The optimal cutoff value of O2-pulse slope ratio for predicting μQFR ≤ 0.8 was 0.4, with area under the curve (AUC) of 0.632 (95 % CI: 0.505-0.759, p = 0.032). The total discordance rate between O2-pulse slope ratio and μQFR was 27.5 %, with 13 patients (9.4 %) being classified as mismatch (O2-pulse slope ratio > 0.4 and μQFR ≤ 0.8) and 25 patients being classified as reverse-mismatch (O2-pulse slope ratio ≤ 0.4 and μQFR > 0.8). Angiography-derived microvascular resistance was independently associated with mismatch (OR 0.07; 95 % CI: 0.01-0.38, p = 0.002) and reverse-mismatch (OR 9.76; 95 % CI: 1.47-64.82, p = 0.018).
Conclusion
Our findings demonstrate the potential of the CPET-derived O2-pulse slope ratio for assessing myocardial ischemia in stable CAD patients.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, East Hospital, Tongji University, Shanghai 200120, China.
- Department of Cardiology, Shanghai East Hospital JI'AN Hospital, Ji'an, Jiangxi 343000, China.
- Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, South Korea.
Förderung
- Shanghai City Pudong New Area People's Government
Zitieren
APA
Geng, L., Huang, S., Zhang, T., Li, J., Wang, L., Zhou, J., Gao, L., Wang, Y., Li, J., Guo, W., Li, Y., & Zhang, Q. (2024). The association between O2-pulse slope ratio and functional severity of coronary stenosis: A combined cardiopulmonary exercise testing and quantitative flow ratio study. IJC Heart & Vasculature, 52, 101409. https://doi.org/10.1016/j.ijcha.2024.101409
Vancouver
Geng L, Huang S, Zhang T, Li J, Wang L, Zhou J, et al. The association between O2-pulse slope ratio and functional severity of coronary stenosis: A combined cardiopulmonary exercise testing and quantitative flow ratio study. IJC Heart & Vasculature. 2024;52:101409. doi:10.1016/j.ijcha.2024.101409
BibTeX
@article{Geng2024,
author = {Geng, Liang and Huang, Shangwei and Zhang, Tingting and Li, Jimin and Wang, Lijie and Zhou, Junyan and Gao, Liming and Wang, Yunkai and Li, Jiming and Guo, Wei and Li, Ying and Zhang, Qi},
title = {The association between O2-pulse slope ratio and functional severity of coronary stenosis: A combined cardiopulmonary exercise testing and quantitative flow ratio study},
journal = {IJC Heart & Vasculature},
year = {2024},
volume = {52},
pages = {101409},
doi = {10.1016/j.ijcha.2024.101409}
}
EUVIMED