EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A comparison of different methods to maximise signal extraction when using central venous pressure to optimise atrioventricular delay after cardiac surgery

Ioana Cretu, Alexander Tindale, Maysam Abbod, Wamadeva Balachandran, Ashraf W Khir, Hongying Meng

IJC Heart & Vasculature · 2024-04 · 51 · 101382

DOI: 10.1016/j.ijcha.2024.101382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IJC Heart & Vasculature, 2024-04. Verfasst von Ioana Cretu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Brunel University London, London, UK. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Our group has shown that central venous pressure (CVP) can optimise atrioventricular (AV) delay in temporary pacing (TP) after cardiac surgery. However, the signal-to-noise ratio (SNR) is influenced both by the methods used to mitigate the pressure effects of respiration and the number of heartbeats analysed. This paper systematically studies the effect of different analysis methods on SNR to maximise the accuracy of this technique.

Methods

We optimised AV delay in 16 patients with TP after cardiac surgery. Transitioning rapidly and repeatedly from a reference AV delay to different tested AV delays, we measured pressure differences before and after each transition. We analysed the resultant signals in different ways with the aim of maximising the SNR: (1) adjusting averaging window location (around versus after transition), (2) modifying window length (heartbeats analysed), and (3) applying different signal filtering methods to correct respiratory artefact.

Results

(1) The SNR was 27 % higher for averaging windows around the transition versus post-transition windows. (2) The optimal window length for CVP analysis was two respiratory cycle lengths versus one respiratory cycle length for optimising SNR for arterial blood pressure (ABP) signals. (3) Filtering with discrete wavelet transform improved SNR by 62 % for CVP measurements. When applying the optimal window length and filtering techniques, the correlation between ABP and CVP peak optima exceeded that of a single cycle length (R = 0.71 vs. R = 0.50, p < 0.001).

Conclusion

We demonstrated that utilising a specific set of techniques maximises the signal-to-noise ratio and hence the utility of this technique.

Schlagwörter

Stichwörter der Autor:innen

Atrioventricular delayCRTCVPFilteringOptimisationTemporary pacing

Autor:innen und Institutionen

  • Brunel University London, London, UK.
  • Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London, UK.
  • Durham University, Durham, UK.

Förderung

  • British Heart Foundation

Zitieren

APA

Cretu, I., Tindale, A., Abbod, M., Balachandran, W., Khir, A. W., & Meng, H. (2024). A comparison of different methods to maximise signal extraction when using central venous pressure to optimise atrioventricular delay after cardiac surgery. IJC Heart & Vasculature, 51, 101382. https://doi.org/10.1016/j.ijcha.2024.101382

Vancouver

Cretu I, Tindale A, Abbod M, Balachandran W, Khir AW, Meng H. A comparison of different methods to maximise signal extraction when using central venous pressure to optimise atrioventricular delay after cardiac surgery. IJC Heart & Vasculature. 2024;51:101382. doi:10.1016/j.ijcha.2024.101382

BibTeX
@article{Cretu2024,
  author = {Cretu, Ioana and Tindale, Alexander and Abbod, Maysam and Balachandran, Wamadeva and Khir, Ashraf W and Meng, Hongying},
  title = {A comparison of different methods to maximise signal extraction when using central venous pressure to optimise atrioventricular delay after cardiac surgery},
  journal = {IJC Heart & Vasculature},
  year = {2024},
  volume = {51},
  pages = {101382},
  doi = {10.1016/j.ijcha.2024.101382}
}
Kostenlos starten →