Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis
Indian Heart Journal · 2026-11
DOI: 10.1016/j.ihj.2026.11.147 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Indian Heart Journal, 2026-11. Verfasst von Dr Sundar Chidambaram und 11 weiteren Autor:innen. Beteiligte Einrichtung: Kauvery Hospital, Vadapalani, Chennai, India. Electronic address: sundarsaivimal@gmail.com. Die Arbeit nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND/OBJECTIVES: The comparative performance of balloon-expandable (BEV) and self-expanding (SEV) transcatheter heart valves in bicuspid aortic valve (BAV) stenosis remains uncertain. METHODS: We systematically reviewed contemporary BAV-TAVR literature published from 2015 to 2025. The broader qualitative evidence map comprised 69 reports, including device-specific and comparative cohorts; however, only studies with extractable arm-level BEV-versus-SEV data were eligible for quantitative comparative pooling. RESULTS: Three head-to-head cohorts contributed to early/30-day device success (BEV 302/353; SEV 160/181). The pooled RR for SEV versus BEV was 1.03 (95% CI 0.96-1.09; I2=0%). Two cohorts contributed to 30-day permanent pacemaker implantation (PPI), showing a numerically higher but non-significant risk with SEV (RR 2.01; 95% CI 0.93-4.37; I2=0%). Only one study provided compatible 30-day arm-level data for moderate-or-greater paravalvular leak (PVL), precluding pooling. Adjusted and single-arm observational evidence suggested possible platform-specific differences in hemodynamics, PVL and conduction outcomes, but these data were not interpreted as evidence of comparative equivalence or superiority. CONCLUSIONS: Available head-to-head evidence does not demonstrate a clear difference in early device success between contemporary BEV and SEV in BAV, but the evidence is sparse, predominantly observational and imprecise. The findings should not be interpreted as proof of equivalence. Prospective comparative studies with standardized BAV phenotyping are required.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kauvery Hospital, Vadapalani, Chennai, India. Electronic address: sundarsaivimal@gmail.com.
- Kauvery Hospital, Vadapalani, Chennai, India.
- Senior Consultant Interventional Cardiologist, Sri Ramachandra Institute of Higher Education and Research (SRMC), Chennai, India.
- Consultant Interventional Cardiologist, St Boniface Hospital, University of Manitoba, Canada.
- Professor of Medicine (Cardiology), UMass Chan Medical School, Worcester MA 01655.
Zitieren
APA
Chidambaram, D. S., Manokar, D. P., Jebaraj, D., P, D. M., V, D. M., Raja, D. D., Nitheshkumar, D., G, D. S., E, D. S., Senguttuvan, D. N., Shah, D. A. H., & Vaikom S Mahadevan, D. (2026). Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis. Indian Heart Journal. https://doi.org/10.1016/j.ihj.2026.11.147
Vancouver
Chidambaram DS, Manokar DP, Jebaraj D, P DM, V DM, Raja DD, et al. Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis. Indian Heart Journal. 2026. doi:10.1016/j.ihj.2026.11.147
BibTeX
@article{Chidambaram2026,
author = {Chidambaram, Dr Sundar and Manokar, Dr P and Jebaraj, Dr and P, Dr Maheshbabu and V, Dr Mahadevan and Raja, Dr Deepchand and Nitheshkumar, Dr and G, Dr Surendhar and E, Dr Selvaprakash and Senguttuvan, Dr Nagendraboopathy and Shah, Dr Ashish H and Vaikom S Mahadevan, Dr},
title = {Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis},
journal = {Indian Heart Journal},
year = {2026},
doi = {10.1016/j.ihj.2026.11.147}
}
EUVIMED