Ultra-thin everolimus-eluting stents in atherosclerotic lesions: Three years follow-up with subgroup analysis of ultra-long stents
Indian Heart Journal · 2023
DOI: 10.1016/j.ihj.2023.03.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Heart Journal, 2023. Verfasst von Raghava Sarma Polavarapu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: drpvraghav@gmail.com. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Coronary Thrombosis, Percutaneous Coronary Intervention, Myocardial Infarction. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVES: To assess the long-term (3 years) safety and efficacy of Tetrilimus everolimus-eluting stent (EES) and subgroup analysis of outcomes of ultra-long (44/48 mm) Tetrilimus EES implantation in patients with long coronary lesions. MATERIAL AND METHODS: In this observational, single-centre, single-arm, investigator-initiated registry, 558 patients who underwent implantation of Tetrilimus EES for the treatment of coronary artery disease were retrospectively included. The primary endpoint was occurrence of any major adverse cardiac event (MACE) at 12 months follow-up (composite of cardiac death, myocardial infarction [MI], and target lesion revascularization [TLR]) and we hereby report 3 years follow-up data. Stent thrombosis was assessed as a safety endpoint. A subgroup analysis of patients with long coronary lesions is also reported. RESULTS: A total of 558 patients (57.0 ± 10.2 years) received 766 Tetrilimus EES (1.3 ± 0.5 stents/patient) to treat 695 coronary lesions. In subgroup analysis of 143 patients implanted with ultra-long EES, 155 lesions were intervened successfully with only one Tetrilimus EES (44/48 mm) implanted per lesion. At 3 years, event rates of 9.1% MACE with predominance of MI (4.4%), followed by 2.9% TLR and 1.7% cardiac death, and only 1.0% stent thrombosis were reported in overall population, while in a subgroup of patients implanted with ultra-long EES, 10.4% MACE and 1.5% stent thrombosis were reported. CONCLUSIONS: Three years clinical outcomes showed favourable long-term safety and excellent performance of Tetrilimus EES in high-risk patients and complex coronary lesions in routine clinical practice, including a subgroup of patients with long coronary lesions, with acceptable primary and safety endpoints.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: drpvraghav@gmail.com.
- Department of Neurosciences, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: drvijayapvr@gmail.com.
- Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: anurag.polavarapu@gmail.com.
- Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: yudhistar1987@gmail.com.
- Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: ravellamk@gmail.com.
- Department of Cardiology, Lalitha Super Specialities Hospital, Guntur, Andhra Pradesh, India. Electronic address: mrachaputi@hotmail.com.
Zitieren
APA
Polavarapu, R. S., Pamidimukkala, V., Polavarapu, A., Siripuram, Y., Ravella, K. C., Rachaputi, M. B. R., Polavarapu, N., Pulivarthi, K. C., Byrapaneni, S., Gangasani, S., Noronha, M., & Chinta, S. R. (2023). Ultra-thin everolimus-eluting stents in atherosclerotic lesions: Three years follow-up with subgroup analysis of ultra-long stents. Indian Heart Journal. https://doi.org/10.1016/j.ihj.2023.03.006
Vancouver
Polavarapu RS, Pamidimukkala V, Polavarapu A, Siripuram Y, Ravella KC, Rachaputi MBR, et al. Ultra-thin everolimus-eluting stents in atherosclerotic lesions: Three years follow-up with subgroup analysis of ultra-long stents. Indian Heart Journal. 2023. doi:10.1016/j.ihj.2023.03.006
BibTeX
@article{Polavarapu2023,
author = {Polavarapu, Raghava Sarma and Pamidimukkala, Vijaya and Polavarapu, Anurag and Siripuram, Yudhistar and Ravella, Keerthika Chowdary and Rachaputi, Murali Babu Rao and Polavarapu, Naren and Pulivarthi, Kalyan Chakravarthi and Byrapaneni, Sravanthi and Gangasani, Sirichandana and Noronha, Michael and Chinta, Srinivasa Rao},
title = {Ultra-thin everolimus-eluting stents in atherosclerotic lesions: Three years follow-up with subgroup analysis of ultra-long stents},
journal = {Indian Heart Journal},
year = {2023},
doi = {10.1016/j.ihj.2023.03.006}
}
EUVIMED