EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

The Accuracy and Trueness of Intraoral Scanners in Neonates With Cleft Lip and Palate: A Comparison of 3D Digital Models

Piyapat Chatborirak, Krisadi Phannarus, Pimsiri Kanpittaya, Pintu-On Chantarawaratit

International Dental Journal · 2025

DOI: 10.1016/j.identj.2025.04.014 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Dental Journal, 2025. Verfasst von Piyapat Chatborirak und 3 weiteren Autor:innen. Beteiligte Einrichtung: Master of Science Program in Dental Biomaterials Science, Graduate School, Chulalongkorn University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Cleft Palate, Cleft Lip, Imaging, Three-Dimensional, Models, Dental. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Faculty of Dentistry, Chulalongkorn University, Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION AND AIMS: Intraoral scanners have recently emerged as a safer and more convenient alternative to traditional impression materials for capturing alveolar morphology in patients with cleft anomalies. This study aimed to assess the accuracy of 3D digital models generated by different intraoral scanners in cleft neonates. Specifically, it focused on evaluating the trueness and precision of these scanners in producing models of unilateral complete cleft lip and palate. METHODS: Forty plaster models of unilateral cleft lip and palate from neonates were analyzed. Inter-segment distances, consisting of 37 anterior and 23 posterior parameters, were measured manually with a digital vernier caliper as the reference. The models were scanned using 5 intraoral scanners: 3Shape TRIOS 4, iTero Element 5D, Medit i700, PANDA P2, and Straumann Virtuo Vivo. The differences between tested values (from 3D scans) and reference values were expressed as error per millimeter. Precision was evaluated by performing repeated scans and measurements on 10% of the models. Statistical analyses included 1-sample t-test, Wilcoxon test, and Friedman test, with a significance level of 0.05. Results were further validated through 3D superimposition using Geomagic Control X software. RESULTS: Observer reliability was excellent, with an ICC value of 1.000. Significant differences in trueness were found for the Medit i700 scanner, with higher errors for posterior inter-segment distances (P = .021) and anterior distances when compared to other scanners (P = .001 to .013). Precision showed excellent agreement across all scanners (ICC = 0.999 to 1.000). CONCLUSION: While all scanners met clinical acceptability standards, the Medit i700 demonstrated lower trueness in certain parameters. CLINICAL RELEVANCE: This study highlights the importance of scanner selection for accurate digital model generation for cleft neonates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cleft PalateCleft LipImaging, Three-DimensionalModels, DentalHumansInfant, NewbornReproducibility of ResultsModels, AnatomicMale

Stichwörter der Autor:innen

AccuracyCleft lip and palateDigital modelIntraoral scannerNeonatesSuperimposition

Autor:innen und Institutionen

  • Master of Science Program in Dental Biomaterials Science, Graduate School, Chulalongkorn University, Bangkok, Thailand.
  • Dental Department, Queen Sirikit National Institute of Child Health, Bangkok, Thailand.
  • Department of Orthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
  • Department of Orthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. Electronic address: pintuon@gmail.com.

Förderung

  • Faculty of Dentistry, Chulalongkorn University
  • Chulalongkorn University

Zitieren

APA

Chatborirak, P., Phannarus, K., Kanpittaya, P., & Chantarawaratit, P. O. (2025). The Accuracy and Trueness of Intraoral Scanners in Neonates With Cleft Lip and Palate: A Comparison of 3D Digital Models. International Dental Journal. https://doi.org/10.1016/j.identj.2025.04.014

Vancouver

Chatborirak P, Phannarus K, Kanpittaya P, Chantarawaratit PO. The Accuracy and Trueness of Intraoral Scanners in Neonates With Cleft Lip and Palate: A Comparison of 3D Digital Models. International Dental Journal. 2025. doi:10.1016/j.identj.2025.04.014

BibTeX
@article{Chatborirak2025,
  author = {Chatborirak, Piyapat and Phannarus, Krisadi and Kanpittaya, Pimsiri and Chantarawaratit, Pintu-On},
  title = {The Accuracy and Trueness of Intraoral Scanners in Neonates With Cleft Lip and Palate: A Comparison of 3D Digital Models},
  journal = {International Dental Journal},
  year = {2025},
  doi = {10.1016/j.identj.2025.04.014}
}
Kostenlos starten →