Precise anatomical landmark annotation of the cardiac conduction system on cardiac computed tomography angiography
Heart Rhythm · 2026-11
DOI: 10.1016/j.hrthm.2026.11.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2026-11. Verfasst von Justin T Tretter und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hobart Healthcare Research Institute, London, United Kingdom. Electronic address: trettej3@ccf.org. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: CTA-based estimation of the conduction system from anatomical landmarks underpins a visualization platform (CARA) used in structural heart interventions and conduction system pacing. OBJECTIVE: To quantify the precision and reliability of the annotation method and the bias of trained readers relative to an expert reference standard. METHODS: The expert who defined the method and 6 trained readers each annotated 8 landmarks representing the sinus and atrioventricular nodes, His bundle course (Point B), left bundle branch origin (Point C), and course of Bachmann's bundle (B2-B5), in addition to the three aortic leaflet nadirs on 50 CTA studies in 3 sessions. Repeatability and reproducibility were assessed, referenced to clinically accepted error margins (2-5 mm). Intraclass correlations (ICC) were computed on heights above the aortic annular plane. 3D bias relative to the expert was tested for equivalence within half the margin. RESULTS: Repeatability SD was 1.67-3.98 mm and reproducibility SD 2.03-5.60 mm; all mean deviations were within margin, with 88.6-97.4% of repeat reads and 71.4-94.9% of reader means within margin. Inter-observer ICC on annular heights was 0.76-0.82 for the atrioventricular and 0.79-0.98 for the atrial points. Shared bias relative to the expert was 0.14-3.24 mm, within margin for all landmarks and equivalent within half the margin for sinus node, Point B, B2 and B3; at B3 and B2, 95% and 83% of the apparent separation was repeatability noise. CONCLUSION: The method meets its clinically accepted margins with millimeter precision and good-to-excellent reliability, and transfers from expert to trained readers with bias within margin.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hobart Healthcare Research Institute, London, United Kingdom. Electronic address: trettej3@ccf.org.
- CARA Medical Ltd., Rochdale, United Kingdom.
- Hobart Healthcare Research Institute, London, United Kingdom.
Zitieren
APA
Tretter, J. T., Asyraf, T., Ugarteburu, M., Spaziani, S., Perez-Salas, N., Webb, N., Zaretsky, L., & Ben-Haim, S. (2026). Precise anatomical landmark annotation of the cardiac conduction system on cardiac computed tomography angiography. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.11.016
Vancouver
Tretter JT, Asyraf T, Ugarteburu M, Spaziani S, Perez-Salas N, Webb N, et al. Precise anatomical landmark annotation of the cardiac conduction system on cardiac computed tomography angiography. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.11.016
BibTeX
@article{Tretter2026,
author = {Tretter, Justin T and Asyraf, Tarikh and Ugarteburu, Maialen and Spaziani, Stefano and Perez-Salas, Nicole and Webb, Nathan and Zaretsky, Lev and Ben-Haim, Shlomo},
title = {Precise anatomical landmark annotation of the cardiac conduction system on cardiac computed tomography angiography},
journal = {Heart Rhythm},
year = {2026},
doi = {10.1016/j.hrthm.2026.11.016}
}
EUVIMED