EUVIMEDEUVIMED entdecken
Open Access

VERSA: Omnipolar vector mapping from arbitrarily positioned electrodes

Jonah A Majumder, Sarah M Schwartz, Marcus Talke, Lawrence Zeldin, Edward J Ciaccio, Elaine Y Wan, Angelo Biviano, Geoffrey Rubin, Jessica Hennessey, Hirad Yarmohammadi, Jose Dizon, Carmine Sorbera und 7 weitere

Heart Rhythm · 2026-08 · 23 (8) · e1594-e1608

DOI: 10.1016/j.hrthm.2026.01.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2026-08. Verfasst von Jonah A Majumder und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, New York. Hauptthemen laut MEDLINE: Heart Conduction System, Electrophysiologic Techniques, Cardiac, Catheter Ablation, Body Surface Potential Mapping. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIGMS NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate assessment of arrhythmia propagation can help identify ablation targets, but current methods are limited by local activation time (LAT) variability, catheter orientation dependence, and inconsistent sampling density. OBJECTIVE: This study aimed to extend LAT-independent omnipolar technology to catheters with arbitrary electrode arrangements, compare estimates with LAT-derived equivalents, and demonstrate a weighted resampling algorithm that produces clear and robust visualizations of wavefront propagation. METHODS: Omnipolar estimates of conduction velocity (CV), activation direction (AD), and voltage were computed from electroanatomic mapping data from 34 scar-related reentrant atrial tachycardias and 1 ventricular tachycardia mapped with PENTARAY and OCTARAY catheters. Estimates were compared with conventional analogs to assess concordance, both globally and after stratification by anatomic region. To overcome sampling nonuniformity, a distance-weighted vector estimation, resampling, and smoothing algorithm (VERSA) was devised to render propagation metrics (CV and AD) into intuitive visualizations. Resulting VERSA maps were assessed qualitatively for their ability to convey local propagation and their agreement with conventional activation maps. RESULTS: Across all cases, omnipolar CV was higher than LAT-based CV, whereas differences in AD were negligible. Omnipolar voltages were significantly higher than the corresponding maximum bipolar voltages. The proposed VERSA maps intuitively depicted wavefront propagation, agreed broadly with activation maps, and illustrated conduction block, conduction breakthrough, and overall patterns of reentry. CONCLUSION: Extending omnipolar technology to arbitrary electrode arrangements and visualizing measurements in VERSA maps can elucidate wavefront propagation in reentrant tachycardias without the need for LAT annotation. These methods could facilitate better interpretation of complex arrhythmia patterns and more effective ablation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Conduction SystemElectrophysiologic Techniques, CardiacCatheter AblationBody Surface Potential MappingTachycardia, VentricularHumansAlgorithmsElectrodes

Stichwörter der Autor:innen

3D visualizationActivation directionAtrial tachycardiaConduction velocityMultielectrode cathetersOmnipolar technologyVector mapping

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, New York.
  • Department of Medicine, Columbia University Vagelos College of Physicians and Surgeons, New York, New York.
  • Department of Cardiovascular Medicine, Gagnon Cardiovascular Institute, Morristown Medical Center/Atlantic Health System, Morristown, New Jersey.
  • Division of Cardiology, Columbia University Vagelos College of Physicians and Surgeons, New York, New York.
  • Division of Cardiology, New York Presbyterian Queens Hospital, Flushing, New York.
  • Division of Cardiology, New York Presbyterian-Weill Cornell Medicine, New York, New York.

Förderung

  • NHLBI NIH HHS
  • NIGMS NIH HHS
  • National Institutes of Health
  • Columbia University

Zitieren

APA

Majumder, J. A., Schwartz, S. M., Talke, M., Zeldin, L., Ciaccio, E. J., Wan, E. Y., Biviano, A., Rubin, G., Hennessey, J., Yarmohammadi, H., Dizon, J., Sorbera, C., Kim, J., Goldbarg, S., Liu, C. F., Miyama, H., Ip, J. E., Hendon, C. P., & Saluja, D. (2026). VERSA: Omnipolar vector mapping from arbitrarily positioned electrodes. Heart Rhythm, 23(8), e1594-e1608. https://doi.org/10.1016/j.hrthm.2026.01.032

Vancouver

Majumder JA, Schwartz SM, Talke M, Zeldin L, Ciaccio EJ, Wan EY, et al. VERSA: Omnipolar vector mapping from arbitrarily positioned electrodes. Heart Rhythm. 2026;23(8):e1594-e1608. doi:10.1016/j.hrthm.2026.01.032

BibTeX
@article{Majumder2026,
  author = {Majumder, Jonah A and Schwartz, Sarah M and Talke, Marcus and Zeldin, Lawrence and Ciaccio, Edward J and Wan, Elaine Y and Biviano, Angelo and Rubin, Geoffrey and Hennessey, Jessica and Yarmohammadi, Hirad and Dizon, Jose and Sorbera, Carmine and Kim, JoonHyuk and Goldbarg, Seth and Liu, Christopher F and Miyama, Hiroshi and Ip, James E and Hendon, Christine P and Saluja, Deepak},
  title = {VERSA: Omnipolar vector mapping from arbitrarily positioned electrodes},
  journal = {Heart Rhythm},
  year = {2026},
  volume = {23},
  number = {8},
  pages = {e1594--e1608},
  doi = {10.1016/j.hrthm.2026.01.032}
}
Kostenlos starten →