Left ventricular subendocardial pacing provides the same left ventricular synchrony and work efficiency as direct left bundle branch capture
Heart Rhythm · 2026
DOI: 10.1016/j.hrthm.2025.12.047 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2026. Verfasst von Lukas Poviser und 3 weiteren Autor:innen. Beteiligte Einrichtung: Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Bundle of His, Bundle-Branch Block, Heart Ventricles. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Charles University, Ministerstvo Zdravotnictví Ceské Republiky, European Commission.
Abstract (Originalsprache)
BACKGROUND: Left ventricular (LV) septal myocardial pacing (LVSP) is present in the areas where left bundle branch (LBB) capture is not feasible with high pacing output (general LVSP), or in LV subendocardial locations, where it transits from LBB pacing (LBBP) during the decremental output pacing (LV subendocardial pacing [LVSeP]). OBJECTIVE: This study aimed to compare electrical ventricular synchrony and acute hemodynamic response between LBBP and LVSeP. METHODS: Consecutive cardiac resynchronization therapy (CRT) patients with transition from nonselective left bundle branch capture to LVSeP during decremental output pacing were enrolled. Ventricular dyssynchrony was assessed using ultra-high-frequency electrocardiogram. The acute hemodynamic response was assessed using a high-precision hemodynamic protocol with invasive measurements of systolic blood pressure. An invasive intracardiac mapping of the left ventricular septum was performed during both captures. RESULTS: The study included 21 patients. LVSeP and LBBP had the same QRS duration (159 ± 18 ms vs 151 ± 15 ms, P = .26), but LVSeP had a longer V6RWPT (98 ± 13 ms vs 79 ± 12 ms, P < .001) and post-pacing isoelectric interval (48 ± 9 vs 39 ± 9, P < .001). However, no significant difference was observed in LV synchrony (14 ± 5 ms vs 16 ± 6 ms, P = .21) and average systolic blood pressure (121 ± 18 mmHg vs 122 ± 17 mmHg, P = .78). Intracardiac mapping of one patient showed that both LVSeP and LBBP activated the LV septum at the recording site via the His-Purkinje system. CONCLUSION: In CRT candidates, LVSeP preserved LV synchrony and acute hemodynamic response at the same level as direct LBBP. Further clinical research is warranted to better understand the differences between various types of left septal pacing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic.
- Department of Cardiology, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, London, United Kingdom.
- Cardiocenter, Third Faculty of Medicine, Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic. Electronic address: karol.curila@fnkv.cz.
Förderung
- Charles University
- Ministerstvo Zdravotnictví Ceské Republiky
- European Commission
Zitieren
APA
Poviser, L., Stros, P., Whinnett, Z., & Curila, K. (2026). Left ventricular subendocardial pacing provides the same left ventricular synchrony and work efficiency as direct left bundle branch capture. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2025.12.047
Vancouver
Poviser L, Stros P, Whinnett Z, Curila K. Left ventricular subendocardial pacing provides the same left ventricular synchrony and work efficiency as direct left bundle branch capture. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2025.12.047
BibTeX
@article{Poviser2026,
author = {Poviser, Lukas and Stros, Petr and Whinnett, Zachary and Curila, Karol},
title = {Left ventricular subendocardial pacing provides the same left ventricular synchrony and work efficiency as direct left bundle branch capture},
journal = {Heart Rhythm},
year = {2026},
doi = {10.1016/j.hrthm.2025.12.047}
}
EUVIMED