Vergleichsstudie in der Zeitschrift Heart Rhythm, 2026-03. Verfasst von Damian Laan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Catheter Ablation, Tomography, X-Ray Computed, Magnetic Resonance Imaging, Cine. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Netherlands Academy of Arts and Sciences, Amsterdam Cardiovascular Sciences, Netherlands Heart Institute.
Abstract (Originalsprache)
BACKGROUND: Advanced postprocessing of late gadolinium enhancement cardiac magnetic resonance (CMR) and computed tomography (CCT) imaging increasingly guides ventricular tachycardia ablation. However, a direct comparison between 2 widely adopted platforms, ADAS 3D LV (Adas3D Medical) and inHEART (IHU Liryc/Inria), is lacking. OBJECTIVE: This study aimed to compare CMR- and CCT-derived ventricular substrate models generated by ADAS 3D and inHEART in patients with ischemic and nonischemic cardiomyopathy undergoing ventricular tachycardia ablation. METHODS: Patients who underwent both CCT and late gadolinium enhancement CMR before ablation were retrospectively included. ADAS 3D models were generated on-site, whereas inHEART models were processed remotely. Substrate models were evaluated using a custom scoring system incorporating quantitative (scar mass, transmurality) and qualitative parameters (wall thickness, scar delineation, and conduction corridors). Electroanatomic maps (EAMs) assessed correspondence between low-voltage and ablation regions, with imaging-defined corridors. RESULTS: 16 patients (n = 8 ischemic, n = 8 nonischemic) were analyzed; 12 had detailed EAM data. Scar core and border zone measurements were comparable between platforms in both subgroups (all P > .05). ADAS 3D showed slightly higher visualization scores, particularly in nonischemic cardiomyopathy, although differences were not statistically significant. Spatial concordance between imaging-derived scar and EAM-defined ablation areas was good to excellent in 10 of 12 cases. CONCLUSION: ADAS 3D and inHEART demonstrated high concordance in scar quantification and substrate characterization, with comparable performance across cardiomyopathy types. Given their complementary strengths, platform choice should be guided by procedural goals, imaging availability, operator experience, and institutional context, as each system offers distinct advantages. Prospective studies are needed to evaluate the impact on procedural success and long-term outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands.
- Adas3D Medical S.L., Barcelona, Spain.
- inHEART SAS, Pessac, France.
- Department of Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands; School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom. Electronic address: p.bhag…
Förderung
- Royal Netherlands Academy of Arts and Sciences
- Amsterdam Cardiovascular Sciences
- Netherlands Heart Institute
- King's College London
- Netherlands Heart Foundation
- Guy's and St Thomas' NHS Foundation Trust
- National Institute for Health and Care Research
Zitieren
APA
Laan, D., Hopman, L. H. G. A., Figueras I Ventura, R. M., Soré, B., Allaart, C. P., Kemme, M. J. B., Götte, M. J. W., Postema, P. G., & Bhagirath, P. (2026). Ventricular tachycardia substrate mapping with cardiac computed tomography and cardiac magnetic resonance imaging: Head-to-head comparison of two clinically available postprocessing platforms. Heart Rhythm, 23(3), 721-729. https://doi.org/10.1016/j.hrthm.2025.09.028
Vancouver
Laan D, Hopman LHGA, Figueras I Ventura RM, Soré B, Allaart CP, Kemme MJB, et al. Ventricular tachycardia substrate mapping with cardiac computed tomography and cardiac magnetic resonance imaging: Head-to-head comparison of two clinically available postprocessing platforms. Heart Rhythm. 2026;23(3):721-729. doi:10.1016/j.hrthm.2025.09.028
BibTeX
@article{Laan2026,
author = {Laan, Damian and Hopman, Luuk H G A and Figueras I Ventura, Rosa M and Soré, Bruno and Allaart, Cornelis P and Kemme, Michiel J B and Götte, Marco J W and Postema, Pieter G and Bhagirath, Pranav},
title = {Ventricular tachycardia substrate mapping with cardiac computed tomography and cardiac magnetic resonance imaging: Head-to-head comparison of two clinically available postprocessing platforms},
journal = {Heart Rhythm},
year = {2026},
volume = {23},
number = {3},
pages = {721--729},
doi = {10.1016/j.hrthm.2025.09.028}
}
EUVIMED