Pulsed field ablation in the elderly by a pentaspline multielectrode catheter: Safety, efficacy, and comparison with cryoballoon and radiofrequency devices
Heart Rhythm · 2025
DOI: 10.1016/j.hrthm.2025.01.025 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Heart Rhythm, 2025. Verfasst von Kazutaka Nakasone und 28 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brus…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cryosurgery, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Catheter ablation is an effective treatment of atrial fibrillation. Pulsed field ablation (PFA) has emerged as a novel energy modality that relies on high-voltage electric fields to achieve cardiac tissue ablation. Data on its efficacy in the elderly are scarce. OBJECTIVE: This study aimed to evaluate the procedural details and clinical outcomes of PFA in patients >75 years old. METHODS: Consecutive patients with atrial fibrillation >75 years old undergoing PFA with the Farapulse system were enrolled at 6 high-volume centers. Procedural details and clinical outcomes were compared with those of patients undergoing second-generation cryoballoon ablation (CBA) and radiofrequency ablation (RFA). RESULTS: Of 983 patients, 221 underwent PFA, 216 CBA, and 546 RFA. Procedure times were shorter with PFA (72 ± 30 minutes) compared with CBA (77 ± 27 minutes) and RFA (99 ± 23 minutes; P < .001). Extra-pulmonary vein ablation was performed in 74.2% PFA, 9.7% CBA, and 42.1% RFA (P < .001). The major complication rate was 1.01% (n = 10) and was not significantly different between groups (1 PFA, 2 CBA, and 7 RFA; P = .578). Minor complications were observed in 1.4% PFA, 5.1% CBA, and 3.5% RFA (P = .093). The 1-year atrial tachyarrhythmia freedom in the propensity score-matched population was 77.2% with PFA, 80.8% with CBA, and 74.9% with RFA; P = .52). CONCLUSION: PFA is a safe and effective option for elderly patients, offering the advantage of enabling extra-pulmonary vein ablation without the concern of thermal injury risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks GUARD-Heart, Brussels, Belgium; Divis…
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks GUARD-Heart, Brussels, Belgium; Texas…
- Arrhythmology Unit, Ospedale Isola Tiberina-Gemelli Isola, Rome, Italy.
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France.
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks GUARD-Heart, Brussels, Belgium.
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks GUARD-Heart, Brussels, Belgium; First…
Zitieren
APA
Nakasone, K., Della Rocca, D. G., Magnocavallo, M., Betancur, A., Vetta, G., Pannone, L., Sorgente, A., Audiat, C., Rodriguez, J., Doundoulakis, I., Nekic, A., Velagić, V., Polselli, M., Mohanty, S., Marcon, L., Sieira, J., Ströker, E., Bala, G., Bianchi, S., …, & HRMC Investigators (2025). Pulsed field ablation in the elderly by a pentaspline multielectrode catheter: Safety, efficacy, and comparison with cryoballoon and radiofrequency devices. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2025.01.025
Vancouver
Nakasone K, Della Rocca DG, Magnocavallo M, Betancur A, Vetta G, Pannone L, et al. Pulsed field ablation in the elderly by a pentaspline multielectrode catheter: Safety, efficacy, and comparison with cryoballoon and radiofrequency devices. Heart Rhythm. 2025. doi:10.1016/j.hrthm.2025.01.025
BibTeX
@article{Nakasone2025,
author = {Nakasone, Kazutaka and Della Rocca, Domenico G and Magnocavallo, Michele and Betancur, Andres and Vetta, Giampaolo and Pannone, Luigi and Sorgente, Antonio and Audiat, Charles and Rodriguez, Jesus and Doundoulakis, Ioannis and Nekic, Andrija and Velagić, Vedran and Polselli, Marco and Mohanty, Sanghamitra and Marcon, Lorenzo and Sieira, Juan and Ströker, Erwin and Bala, Gezim and Bianchi, Stefano and Almorad, Alexandre and Combes, Stephane and Tsiachris, Dimitrios and Sarkozy, Andrea and Natale, Andrea and Boveda, Serge and Rossi, Pietro and de Asmundis, Carlo and Chierchia, Gian-Battista and HRMC Investigators, HRMC Investigators},
title = {Pulsed field ablation in the elderly by a pentaspline multielectrode catheter: Safety, efficacy, and comparison with cryoballoon and radiofrequency devices},
journal = {Heart Rhythm},
year = {2025},
doi = {10.1016/j.hrthm.2025.01.025}
}
EUVIMED