EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-month success rates

Florent Farnir, Sevasti-Maria Chaldoupi, Ben J M Hermans, Frédéric Farnir, Zarina Habibi, Kezia Jerltorp, Dominique Verhaert, Ulrich Schotten, Bart Maesen, Kevin Vernooy, Justin Luermans, Dominik Linz

Heart Rhythm · 2025

DOI: 10.1016/j.hrthm.2025.01.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2025. Verfasst von Florent Farnir und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Heart Atria. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020, Novo Nordisk Fonden, Hartstichting.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Focal pulsed field ablation (F-PFA) integrated in electroanatomic mapping systems allows tailored lesion sets in patients with atrial fibrillation (AF). OBJECTIVE: We aimed to determine feasibility, safety, and 6-month outcome of F-PFA for a tailored substrate-based catheter ablation approach in patients with AF and advanced atrial substrate. METHODS: Consecutive patients with AF and advanced atrial substrate treated by an F-PFA system (CardioFocus) through contact force-sensing catheters integrated in electroanatomic mapping systems were prospectively enrolled. The tailored substrate-based catheter ablation approach included isolation of all pulmonary veins with wide area circumferential ablation, posterior wall isolation, mitral anterior line, and cavotricuspid isthmus ablation, according to substrate. At 6 months, feasibility, arrhythmia recurrence, and safety were evaluated. RESULTS: In 83 patients (33% female; indexed left atrial volume, 44 ± 15 mL/m2; 80% persistent AF or atrial flutter [AFl]; 57% redo procedures), successful de novo pulmonary vein isolation was performed in 36 patients and pulmonary vein reisolation in 30 patients. Mitral anterior line was performed in 19 patients with atypical AFl or anterior low-voltage areas; posterior wall isolation was performed in 38 patients with low-voltage areas or evoked delayed electrograms during premature atrial extrastimuli; and cavotricuspid isthmus ablation was performed in 24 patients with typical AFl. Median procedural and fluoroscopy times were 115 and 7 minutes, respectively. No complications occurred. At 6 months, arrhythmia recurred in 30 of 83 patients (21 AF; 9 atypical AFl). CONCLUSION: Tailored substrate-based F-PFA in patients with AF and advanced atrial substrate is safe and effective. Acute procedural success was 100% with 64% freedom from arrhythmias after 6 months.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsHeart AtriaHeart Conduction SystemBody Surface Potential MappingHumansFemaleMaleMiddle AgedTreatment OutcomeProspective StudiesFollow-Up StudiesRecurrenceAgedFeasibility StudiesTime Factors

Stichwörter der Autor:innen

Atrial fibrillationFirst-pass isolationFocal ablationPosterior wall isolationPulsed field ablationSafety

Autor:innen und Institutionen

  • Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands.
  • Department of Biostatistics and Bioinformatics, FARAH, Faculty of Veterinary Medicine, University of Liege, Liège, Belgium.
  • Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Cardiology, Radboud University Medical Center, Nijmegen, T…
  • Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Cardiothoracic Surgery, Cardiovascular Research Institute…
  • Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Science…

Förderung

  • Horizon 2020
  • Novo Nordisk Fonden
  • Hartstichting
  • Hjerteforeningen

Zitieren

APA

Farnir, F., Chaldoupi, S. M., Hermans, B. J. M., Farnir, F., Habibi, Z., Jerltorp, K., Verhaert, D., Schotten, U., Maesen, B., Vernooy, K., Luermans, J., & Linz, D. (2025). A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-month success rates. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2025.01.015

Vancouver

Farnir F, Chaldoupi SM, Hermans BJM, Farnir F, Habibi Z, Jerltorp K, et al. A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-month success rates. Heart Rhythm. 2025. doi:10.1016/j.hrthm.2025.01.015

BibTeX
@article{Farnir2025,
  author = {Farnir, Florent and Chaldoupi, Sevasti-Maria and Hermans, Ben J M and Farnir, Frédéric and Habibi, Zarina and Jerltorp, Kezia and Verhaert, Dominique and Schotten, Ulrich and Maesen, Bart and Vernooy, Kevin and Luermans, Justin and Linz, Dominik},
  title = {A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-month success rates},
  journal = {Heart Rhythm},
  year = {2025},
  doi = {10.1016/j.hrthm.2025.01.015}
}
Kostenlos starten →