Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience
Heart Rhythm · 2024
DOI: 10.1016/j.hrthm.2024.05.042 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Heart Rhythm, 2024. Verfasst von Antonio Dello Russo und 13 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Biomedical Sciences and Public Health, Marche Polytechn…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 46-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Pulsed field ablation (PFA) and very high-power short-duration (vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA vs vHPSD are currently unknown. OBJECTIVE: The study aimed to compare PFA with vHPSD for the treatment of paroxysmal or persistent AF. METHODS: We conducted an observational, multicenter study enrolling 534 consecutive patients (63 ± 9 years; 36% female) with paroxysmal (n = 368 [69%]) or persistent (n = 166 [31%]) AF undergoing ablation by either PFA (Farapulse; n = 192) or vHPSD (90 W/4 seconds; QDOT Micro; n = 342) between 2020 and 2023. Atrial tachyarrhythmia recurrence after a 1-month blanking period was the primary efficacy end point and was assessed both overall and in propensity score-matched patients. The primary safety end point was a composite of procedure-related complications. RESULTS: Successful pulmonary vein isolation was achieved in all patients, with shorter procedure duration (PFA,70 minutes; vHPSD, 100 minutes; P < .001) but longer fluoroscopy time (PFA, 15 minutes; vHPSD, 7 minutes; P < .001) in the PFA group. PFA was associated with more frequent use of general anesthesia (P < .001). Primary safety outcome events occurred in 19 patients (3.5%), with similar prevalence in both groups (PFA, 4%; vHPSD, 3%; P = .745). After a median follow-up of 12 (9-12) months, survival free from recurrent atrial tachyarrhythmia was similar between the PFA and vHPSD groups, both overall (12-month estimate: PFA, 75%; vHPSD, 76%; log-rank P = .73) and in propensity score-matched patients (n = 342; 12-month estimate: PFA, 75%; vHPSD, 77%; log-rank P = .980). CONCLUSION: In a large, multicenter experience, PFA was associated with more common use of general anesthesia, shorter procedural times, and longer fluoroscopy exposure compared with vHPSD ablation, with both techniques displaying superimposable safety and efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy; Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy. Electronic address: paolocompagnucci1@gmail.com.
- Division of Cardiology, Cardiovascular and Thoracic Department, "Città della Salute e della Scienza" Hospital, Turin, Italy; Department of Medical Sciences, University of Turin, Turin, Italy.
- Clinica Montevergine, Mercogliano, Avellino, Italy.
- Department of Medical Sciences, University of Turin, Turin, Italy; Clinica Montevergine, Mercogliano, Avellino, Italy.
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy.
Zitieren
APA
Dello Russo, A., Compagnucci, P., Anselmino, M., Schillaci, V., Campanelli, F., Ascione, M. R., Volpato, G., Cipolletta, L., Parisi, Q., Valeri, Y., D'Angelo, L., Chiariello, P., Casella, M., & Solimene, F. (2024). Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.05.042
Vancouver
Dello Russo A, Compagnucci P, Anselmino M, Schillaci V, Campanelli F, Ascione MR, et al. Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.05.042
BibTeX
@article{DelloRusso2024,
author = {Dello Russo, Antonio and Compagnucci, Paolo and Anselmino, Matteo and Schillaci, Vincenzo and Campanelli, Francesca and Ascione, Maria Rosaria and Volpato, Giovanni and Cipolletta, Laura and Parisi, Quintino and Valeri, Yari and D'Angelo, Leonardo and Chiariello, Paola and Casella, Michela and Solimene, Francesco},
title = {Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: Results of a multicenter, real-world experience},
journal = {Heart Rhythm},
year = {2024},
doi = {10.1016/j.hrthm.2024.05.042}
}
EUVIMED