EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Diagnostic accuracy for detecting atrial fibrillation using a novel machine learning algorithm in a blood pressure monitor

Matthew Janik, George Raad, George Nijmeh, Matthew O'Steen, Jason Rasmussen

Heart Rhythm · 2024

DOI: 10.1016/j.hrthm.2024.04.086 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Heart Rhythm, 2024. Verfasst von Matthew Janik und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Division, Wilmington Health, Wilmington, North Carolina. Electronic address: MJanik@wilmingtonhealth.com. Hauptthemen laut MEDLINE: Algorithms, Atrial Fibrillation, Machine Learning. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Omron Healthcare Co Ltd.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Early detection of atrial fibrillation (AF) is key for preventing strokes. Blood pressure monitors (BPMs) with built-in AF screening features have the potential for early detection at home. Recently, 2 BPMs (HEM-7371T1-AZ and HEM-7372T1-AZAZ, Omron Healthcare Co., Ltd.) that share a novel AF screening feature have been developed. Their AF screening feature utilizes an algorithm that incorporates machine learning, with the potential to improve diagnostic accuracy. OBJECTIVE: The purpose of this study was to evaluate the performance of this AF screening feature in a multicenter, prospective clinical study at 5 sites in the United States. METHODS: A total of 559 subjects were enrolled for this study: 267 in AF cohort and 292 in the non-AF cohort. AF screening was performed in all subjects by the 2 Omron BPMs and by 1 Microlife BPM (BP 3MX1-3, WatchBP Home A, Microlife Corp.), and a simultaneous 12-lead electrocardiogram (ECG) was recorded for comparison. All 12-lead ECGs were interpreted by a board-certified cardiologist who was blinded to the BPM results. Sensitivity, specificity, and accuracy for the diagnosis of AF were calculated. RESULTS: Omron HEM-7371T1-AZ BPM had sensitivity of 95.1% (95% confidence interval [CI] 91.8%-97.4%), specificity 98.6% (95% CI 96.6%-99.7%), and accuracy of 97.0% (95% CI 95.2%-98.2%). Equivalent results were obtained with the Omron HEM-7371T1-AZAZ BPM. This compared favorably to the Microlife BPM (sensitivity 78.5%, 95% CI 73.1%-83.3%; specificity 97.6%, 95% CI 95.1%-99.0%; accuracy 88.4%, 95% CI 85.5%-91.0%). CONCLUSION: These data support both home and professional use of these novel Omron BPMs for the detection of AF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsAtrial FibrillationMachine LearningAgedFemaleHumansMaleMiddle AgedBlood PressureBlood Pressure MonitorsElectrocardiographyProspective StudiesReproducibility of ResultsUnited States

Stichwörter der Autor:innen

ArrhythmiaAtrial fibrillationBlood pressure monitorMachine learningScreening

Autor:innen und Institutionen

  • Cardiology Division, Wilmington Health, Wilmington, North Carolina. Electronic address: MJanik@wilmingtonhealth.com.
  • Internal Medicine Division, CarolinaMD, Charlotte, North Carolina.
  • Cardiology Division, Duly Health and Care, Winfield, Illinois.
  • Cardiology Division, Roper St. Francis Physician Partners Coastal Cardiology, Charleston, South Carolina.
  • Cardiology Division, McFarland Clinic, Ames, Iowa.

Förderung

  • Omron Healthcare Co Ltd

Zitieren

APA

Janik, M., Raad, G., Nijmeh, G., O'Steen, M., & Rasmussen, J. (2024). Diagnostic accuracy for detecting atrial fibrillation using a novel machine learning algorithm in a blood pressure monitor. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.04.086

Vancouver

Janik M, Raad G, Nijmeh G, O'Steen M, Rasmussen J. Diagnostic accuracy for detecting atrial fibrillation using a novel machine learning algorithm in a blood pressure monitor. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.04.086

BibTeX
@article{Janik2024,
  author = {Janik, Matthew and Raad, George and Nijmeh, George and O'Steen, Matthew and Rasmussen, Jason},
  title = {Diagnostic accuracy for detecting atrial fibrillation using a novel machine learning algorithm in a blood pressure monitor},
  journal = {Heart Rhythm},
  year = {2024},
  doi = {10.1016/j.hrthm.2024.04.086}
}
Kostenlos starten →