Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation

Thomas Kueffer, Robin Stettler, Jens Maurhofer, Antonio Madaffari, Anita Stefanova, Salik Ur Rehman Iqbal, Gregor Thalmann, Nikola A Kozhuharov, Oskar Galuszka, Helge Servatius, Andreas Haeberlin, Fabian Noti und 3 weitere

Heart Rhythm · 2024-08 · 21 (8) · 1227-1235

DOI: 10.1016/j.hrthm.2024.04.045 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Heart Rhythm, 2024-08. Verfasst von Thomas Kueffer und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; SITEM Center for Translational Medicine and B…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Cryosurgery, Catheter Ablation. Die Arbeit wurde bisher 62-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsCryosurgeryCatheter AblationHumansMaleFemaleMiddle AgedTreatment OutcomeFollow-Up StudiesElectrocardiography, AmbulatoryAgedRecurrenceHeart Conduction SystemRetrospective Studies

Stichwörter der Autor:innen

Cryoballoon ablationPersistent atrial fibrillationPulmonary vein isolationPulsed-field ablationRadiofrequency ablation

Autor:innen und Institutionen

  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; SITEM Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. Electronic address: tobias.reichlin@insel.ch.

Zitieren

APA

Kueffer, T., Stettler, R., Maurhofer, J., Madaffari, A., Stefanova, A., Iqbal, S. U. R., Thalmann, G., Kozhuharov, N. A., Galuszka, O., Servatius, H., Haeberlin, A., Noti, F., Tanner, H., Roten, L., & Reichlin, T. (2024). Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation. Heart Rhythm, 21(8), 1227-1235. https://doi.org/10.1016/j.hrthm.2024.04.045

Vancouver

Kueffer T, Stettler R, Maurhofer J, Madaffari A, Stefanova A, Iqbal SUR, et al. Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation. Heart Rhythm. 2024;21(8):1227-1235. doi:10.1016/j.hrthm.2024.04.045

BibTeX
@article{Kueffer2024,
  author = {Kueffer, Thomas and Stettler, Robin and Maurhofer, Jens and Madaffari, Antonio and Stefanova, Anita and Iqbal, Salik Ur Rehman and Thalmann, Gregor and Kozhuharov, Nikola A and Galuszka, Oskar and Servatius, Helge and Haeberlin, Andreas and Noti, Fabian and Tanner, Hildegard and Roten, Laurent and Reichlin, Tobias},
  title = {Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation},
  journal = {Heart Rhythm},
  year = {2024},
  volume = {21},
  number = {8},
  pages = {1227--1235},
  doi = {10.1016/j.hrthm.2024.04.045}
}